IRIS-Net
DSP, Speaker, Load, Supervision & Test. "Config & Info" provides information about power amplifier type,
firmware revision and configuration. In addition you are able to program the power-on delay, enter power amp and
channel names, and specify functions of the GPIO port. Furthermore, programming job functions (control
functions, which are sent and received via the CAN-network) is also possible. "DSP" allows setting all DSP
parameters and saving them in presets. Recalling presets, import (read from file) and export (save to file) is
possible as well. The DSP parameters include Master EQ, Master Delay, Routing, Channel EQ, X-Over with Level
Trim and Alignment Delay as well as Dynamic functions including compressors and limiters. On the "Speaker" page
you are able to select loudspeaker files with measured frequency and phase responses and assign them to
individual power amplifier channels. This response plots can be displayed in EQ and X-Over windows to allow
optimized parameter settings. "Load" provides information about measured output voltages and currents and the
resulting calculated load. You can set the limits for the allowable impedance range and start impedance tests of a
defined frequency range. Impedance graphs can be saved as reference measurements with tolerance spread.
"Supervision & Test" provides indication of different fault types. You are able to select which failures result in a
fault messages. Activating the pilot tone function is also performed on this page. Also provided is a test tone
generator for manual testing.
13. Password Protection. Each page (layer) can be protected by an individual password. Programming different
access rights is possible as well. Open the password dialog in the Menu Configuration, Passwords.... Enter a
password for the system administrator (probably you) and add new users (New User) if needed. You have to enter
the user names, passwords and access rights. Specifying at least an administrator password and protecting the
configuration page against unwanted access is generally recommended.

How to edit an existing project?

This paragraph explains how to edit a project that already exists. Due to the fact that IRIS-Net provides the possibility
for different users to have different access permissions assigned within a single project, editing options might be
highly restricted by the Administrator.
1.
Start the IRIS-Net program. IRIS-Net starts, creates a new project and opens a new worksheet named "Layer 1".
2.
Open an already existing project. Select File > Open. The Open dialog box appears. Select the desired project
directory and then the according project file (extension .ds) and click on the Open button.
3.
Enter the password (optional). The Login dialog box appears automatically if the project that you are about to
open is password protected. Enter the Administrator user's password in the Enter Password: text field.
4.
Edit the project. Now you are able to edit the project, i.e. change devices, controls and displays/indicators of the
current project. Besides changing parameters and configurations, you can also add new or remove elements. Save
the project (optional). If you have altered the project and want to save the changes, select File > Save to save the
project under the same name. In case you want to save the project under a new name, select File > Save As... and
enter a new file name.

Going On-Line

IRIS-Net allows working off-line or on-line. The two modes differ from each other in the way of selecting executable
operations. Upon opening, the IRIS-Net application is automatically in offline mode. This mode allows the creation and
editing of a project. The dialog that appears when pressing the "On-line" button in the "Button Bar" differs, depending
on the interfaces used in the project. The Ethernet On-line Dialog appears fro each Ethernet interface used in the
project. The CAN On-line Dialog is displayed for each CAN interface that is used.