If requested, enter the administrator password of Windows 7. A DOS window will appear indicating the successful
re-configuration of the firewall.

TPI-8/TPI-12

Updating the IRIS-Net project file
HINT: The following description refers to IRIS-Net version V2.0 or newer. The IRIS-Net version installed at the TPI
must be V1.8.0 or newer. For older version of IRIS-Net (e.g. V1.7.1) please see page 404.
Caution!
Project files including Dante configuration can not be used with TPI-8/TPI-12 touch panels.
!
Consequences
The purpose of this procedure is to build a connection between a PC and a TPI-8/TPI-12 and updating the IRIS-Net
project file of the TPI-8/TPI-12. In the following it is assumed that the file to be transfered is available at the PC.
1.
Connect the network connection of your PC to the Ethernet interface of the TPI-8/TPI-12 directly with a crossover
cable, or with a patch cable and a hub/switch.
2.
Activate the power supply system of the TPI-8/TPI-12.
After some seconds an IRIS-Net project signals the successful start activity of the TPI-8/TPI-12.
3.
Click on Start > All Programs > Accessories > Command Prompt.
The window command prompt appears.
4.
Enter telnet 192.168.1.101 and tap the return button.
The message "Welcome to IRIS" is indicated.
5.
Enter doc*update=start and tap the return button.
Bosch Security Systems B.V.
User Manual
TOUCH PANELS | en
540
2017.05 | 3.20 | F.01U.119.956