General Dsp Parameter Description - Bosch IRIS-Net User Manual

Table of Contents

Advertisement

IRIS-Net
/SERVICE
/GEN
Examples:
/POWER/SWITCH ON switches amp's power on
/TEMP/ACT ? queries the amp temperature
/TEMP/ACT 65 reply to query: 65 °C
/ERRFLAG/ACT ? queries operational state and error flags
/ERRFLAG/ACT POWER,GLOBAL reply to query: Power is On, Global Error detected (Collected Error in external
CAN-devices)
/ERRFLAG/GLOBAL ? queries for which external CAN-devices errors have been detected
/ERRFLAG/GLOBAL 3-4 reply to query: Collected Error Flags on amps 3 and 4 are set

GENERAL DSP PARAMETER DESCRIPTION

Parameter
Value/Settings
level
-128...+6 [dB]
trim level
-30...+6 [dB]
mute
0 / 1
polarity
0 / 1
route
0 / 1 / 2
delay
bypass
0 / 1
eq type
0...5
Bosch Security Systems B.V.
/A
/
SWITCH
/GAIN
/B
...
/
MODE
/
FREQ
U
/MIX
/PRE
Description
-128dB is identical to MUTE
0 = ON, 1 = MUTE
0 = Normal, 1 = Invertiert
0 = IN A, 1 = IN B, 2 = IN A+B
Delay value with unit (time or distance)
HINT: Reading displays the delay value independent
of the saved unit. Writing also stores the stated unit.
0 = ON, 1 = BYPASS
0 = PEQ, 1 = LOSHELV, 2 = HISHELV, 3 = LOCUT, 4 =
HICUT, 5 = ALLPASS
R / W
ON, OFF
R / W
-128...50
[dBu]
R / W
R / W
SINE,
WHITE,
PINK
R / W
10.0...2000
0
.0 [Hz]
R / W
ON, OFF
R / W
ON, OFF
User Manual
REMOTE AMPLIFIER | en
Commands for Test Generator
Generator ON / OFF for channel A
Generator output level for channel A
(identical parameters for channel B)
Test Generator signal type
Test Generator Frequency, when SINE
has been selected
Wanted signal and Generator signal
mixed (ON) or Generator solo (OFF)
Generator signal fed in at the input or
at the output
2017.05 | 3.20 | F.01U.119.956
162

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents