Table of Contents

Advertisement

IRIS-Net

Load

The Load window provides access to all settings and functions for testing and monitoring the load connected to the
amplifier outputs.
The constantly measured output voltage and output current values of the Remote Power Amplifiers are indicated within
the Load window. As soon as the output voltage of the signal present exceeds 150 mV, the resulting load is calculated
and indicated. If the set thresholds are being exceeded or fallen short of, a corresponding message appears in the
Load display of the Amplifier Control Panel. This dialog box permits to independently set the upper and lower
thresholds for each power amp channel.
Within the Load window it is also possible to measure speaker impedance graphs and save them as references. The
frequency range (start frequency, stop frequency) and the generator level of the sine-sweep test signal that is
generated for this test can be adjusted. Specifying a tolerance field for the saved reference graphs is possible as well.
A fault message is displayed in the event that a measurement exceeds or falls short of the tolerance range during
system check. Select the Load window by clicking on the Load tab in the Setup & Control Window.
Bosch Security Systems B.V.
Clicking the button LOAD SPEAKER FILE opens a dialog that
allows the selection of the desired speaker file. Different
loudspeaker files can be found in the Speaker files IRIS-Net
folder. The name of the loaded loudspeaker model is shown in
the black-shaded field on the right.
Clicking the CLEAR SPEAKER DATA button clears the
previously loaded measured speaker data of the selected
channel.
1
1...8
The NUMBER OF SPEAKERS parameter allows the user to
specify the number of speaker systems connected to the
corresponding channel. Doubling the number of speakers
results in a level increase of 6 dB within the selected channel.
Set- ting an amount from 1 to 8 is possible.
User Manual
REMOTE AMPLIFIER | en
2017.05 | 3.20 | F.01U.119.956
139

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents