  • Page 1 Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS Installation and Operation Guide...
  • Page 3: Table Of Contents

    Photobeam 5000 Table of Contents | en Table of contents Introduction About documentation Bosch Security Systems, Inc System overview Features Photobeam overview Console overview Transmitter/receiver dimensions Installation Beam spread Pole mount installation Wall mount installation Wiring Terminal strip overview Wiring distance...
  • Page 4: Introduction

    Bosch Security Systems, Inc Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/. Manufacturing date information is contained in digit no 1 – 3: DDD.
  • Page 5: System Overview

    Photobeam 5000 System overview | en System overview The ISC-FPB1-W60QS, ISC-FPB1-W120QS and ISC-FPB1-W200QS are quad-beam photoelectric detectors designed for indoor and outdoor applications. Consisting of a separate transmitter and receiver, an alarm is activated when a person passes through all four beams.
  • Page 6: Photobeam Overview

    10 ー Horizontal adjustment 4 ー Wire entry 11 ー Console 5 ー Wiring terminals 12 ー Cover 6 ー Detector 13 ー Cover securing screws 7 ー Optical module 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 7: Console Overview

    5 ー Receiver console 2 ー Power Indicator 6 ー Status Indicators 3 ー Function switches 7 ー Sensitivity control 4 ー Beam Power Control 8 ー Alignment check terminals Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 8: Transmitter/Receiver Dimensions

    Callout ﹘ Description Callout ﹘ Description 1 ー Knockout wire entrance 3 ー Center of the Upper Beam 2 ー Center of the Lower Beam 4 ー Wire entrance 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 9: Installation

    Figure 3.1: Beam distance and spread Callout ﹘ Description Callout ﹘ Description 1 ー Transmitter 4 ー Receiver 2 ー Horizontal spread (B) 5 ー Distance (A) 3 ー Vertical spread (C) Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 10: Pole Mount Installation

    Loosen the two base mounting screws and remove the mounting plate by sliding it down. Attach the mounting hardware to the mounting plate using the clamping screws. Refer to the figure below. 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 11 Slide the transmitter onto the mounting plate, and secure using the included screws. Repeat this procedure for the receiver, verify line-of-sight with the transmitter. Wire to the terminal strips. Refer to Wiring, page 13 for wiring procedures. Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 12: Wall Mount Installation

    Callout ー Description Callout ー Description 1 ー Mounting screws 4 ー Device securing screws 2 ー Mounting plate 5 ー Knockout 3 ー Detector 6 ー Wire entry 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 13: Wiring

    Callout ﹘ Description Callout ﹘ Description 1 ー Receiver 4 ー Tamper 2 ー Transmitter 5 ー Alarm output 3 ー Power (non-polarized) 6 ー EDC output Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 14: Wiring Distance

    Selecting the proper wire routes and gauges depend on the number of devices, overall distance, and voltage drop parameters for each individual device. 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 15 3 ー Receiver Notice! The BH12T heater is an optional device. Refer to the BH12T installation instructions (P/N: W. 97.2195) for more information. Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 16: Special Features

    EDC relay has been activated. Notice! Connect the EDC to an input circuit and check the system any time the EDC relay is activated. 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 17: Beam Interruption Time

    The Beam Power Control adjusts the amount of beam energy for optimal range. Figure 5.1: Detection range Callout ﹘ Description 1 ー Short range 2 ー Maximum detection range Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 18: Setup

    Turn the Beam Power Control on the transmitter clockwise to increase beam power. Turn counter-clockwise to decrease beam power. Refer to table below. For UL applications, the interruption time cannot exceed 75 ms. 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 19 Figure 6.3: Beam switch Callout ー Description Callout ー Description 1 ー Transmitter 3 ー Lower beam switch 2 2 ー Upper beam switch 1 4 ー Beam power control Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 20: Optical Alignment

    Level LED - alignment of the Lower Beam Perform the following to align the lower beam. Aligning of the lower beam: Turn on the transmitter Function switch 2 (Lower Beam). 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 21: Volt Meter Alignment

    1 ー Alignment check terminals Notice! Turn on Function switches 1 and 2 of the transmitter after finishing the alignment to verify the monitor LEDs light up once every 3 seconds. Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 22: Operational Check

    Remove the cover from the detector. Verify the tamper input of the control panel detects the status change and indicates the faulted (active) condition. 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.
  • Page 23: Troubleshooting

    Additional information – At least once a year, clean the optical modules and covers with a soft cloth. Perform walk testing to verify correct operation. Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 24: Certifications

    Region Agency Certification UL 639 Intrusion Detection Units and Systems Europe Hereby, Bosch, declares that this transmitter is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC 2016.02 | 03 | F.01U.305.910 Installation and Operation Guide...
  • Page 25: Specifications

    -30° C ー +70° C (-22° F ー 158° F) (95% or less Relative Storage temperature Humidity) IP rating (indoor) IP66 Weight (each) 1200 g (2 lbs) Dimensions 103 x 398 x 99 mm (4.05 x 15.66 x 3.89 in) Bosch Security Systems, Inc. Installation and Operation Guide 2016.02 | 03 | F.01U.305.910...
  • Page 28 Bosch Security Systems, Inc. 130 Perinton Parkway Bosch Sicherheitssysteme GmbH Fairport, NY 14450 Robert-Bosch-Ring 5 85630 Grasbrunn www.boschsecurity.com Germany © Bosch Security Systems, Inc., 2016 www.boschsecurity.com...