Summary of Contents for Endress+Hauser Prosonic S FMU95

  • Page 1: Operating Instructions

    Operating Instructions Prosonic S FMU95 Slot-Index Lists for PROFIBUS DP A U T H O R I Z E D D I S T R I B U T O R : I n s t r u m e n t s A n d C o n t r o l . c o m H o u s t o n , T e x a s U S A s a l e s @ I n s t r u m e n t s A n d C o n t r o l .
  • Page 3: Table Of Contents

    Prosonic S FMU95 - PROFIBUS DP Table of Contents Table of Contents Introduction ..... 4 Slot-Index Lists....5 Resource Block (RB) .
  • Page 4: Introduction

    Introduction Prosonic S FMU95 - PROFIBUS DP Introduction This document comprises the Slot-Index tables for all user parameters of the Prosonic S. The parameters are arranged according to the function blocks of the Prosonic S. All function blocks containing user parameters are taken into account. Some of these blocks are not available in every version of the instrument.
  • Page 5: Slot-Index Lists

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists Slot-Index Lists Resource Block (RB) 2.1.1 Instances Instance Slot Index 2.1.2 Structure Target Mode RBTargetMode Unsigned8 Auto, 8 ... 8 static code RBLockingCode DX104 0 Unsigned16 Auto, 0 ... 65535 2457 non- vol.
  • Page 6 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP distance unit RBDistanceUnit16 DX019 0 Unsigned16 Auto, 1010 : m static 1018 : ft 1013 : mm 1019 : inch temperature unit RBTemperatureUnit16 DX01A 0 100 2 Unsigned16 Auto, 1001 : °C °C...
  • Page 7 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists actual error 6 RBActualError6 116 2 Unsigned16 Auto, 0 ... 65535 dyna- actual error 7 RBActualError7 117 2 Unsigned16 Auto, 0 ... 65535 dyna- actual error 8 RBActualError8 118 2 Unsigned16 Auto, 0 ...
  • Page 8: Slot-Index Lists

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP card3 name RBCard3Name S0050 177 23 VisibleString Auto, ---------- static card3 serial no RBCard3SerialNo S0050 178 16 VisibleString Auto, ---------- static card3 hwversion RBCard3HardwareVersion S0050 179 1 Unsigned8 Auto, 0 ... 255...
  • Page 9 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists download mode RBDownloadMode 206 1 Unsigned8 Auto, 0 : parameter only parameter dyna- 1 : param+cust.map only 2 : mapping only modem sync RBSyncGSMModem S0140 212 1 Unsigned8 Auto, 0 : off...
  • Page 10 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP paste to RBCopyFlowDest 249 2 Unsigned16 Auto, 30220 : flow 1 flow 2 static 30221 : flow 2 start RBStartCopyFlow 250 1 Unsigned8 Auto, 0 : no dyna- 1 : yes View1...
  • Page 11: Display Block (Dy)

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists Display Block (DY) 2.2.1 Instances Instance Slot Index 2.2.2 Structure Target Mode DYTargetMode Unsigned8 Auto, 8 ... 8 non- vol. language DYLanguage DX011 0 Unsigned16 Auto, 0 : English English static 1 : Deutsch 2 : Français...
  • Page 12 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 1 DYInput1Source DX320 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 13 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input1 unit DYInput1Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 14 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 2 DYInput2Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 15 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input2 unit DYInput2Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 16 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 3 DYInput3Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 17 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input3 unit DYInput3Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 18 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 4 DYInput4Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 19 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input4 unit DYInput4Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 20 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 5 DYInput5Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 21 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input5 unit DYInput5Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 22 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 6 DYInput6Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 23 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input6 unit DYInput6Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 24 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 7 DYInput7Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 25 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input7 unit DYInput7Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 26 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 8 DYInput8Source CX000 0 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 27 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input8 unit DYInput8Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 28 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 9 DYInput9Source CX000 0 103 2 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 29 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input9 unit DYInput9Unit16 107 2 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal...
  • Page 30 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 10 DYInput10Source CX000 0 111 2 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 31 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input10 unit DYInput10Unit16 115 2 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal...
  • Page 32: Sum Block (Sx)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP Sum Block (SX) 2.3.1 Instances Instance Slot Index 2.3.2 Structure Target Mode SXTargetMode Unsigned8 Auto, 0 ... 255 non- vol. reset SXResetBlock Unsigned16 Auto, 0 ... 65535 dyna- output SXInput1Source Unsigned16 Auto,...
  • Page 33 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists value 1 SXInput2Value Float Auto, -999999.0 ... 999999.0 SXInp dyna- ut2U nit16 input2 unit SXInput2Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 34 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 1 SXInput4Value Float Auto, -999999.0 ... 999999.0 SXInp dyna- ut4U nit16 input4 unit SXInput4Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 35 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists value 1 SXInput6Value Float Auto, -999999.0 ... 999999.0 SXInp dyna- ut6U nit16 input6 unit SXInput6Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 36 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value 1 SXInput8Value Float Auto, -999999.0 ... 999999.0 SXInp dyna- ut8U nit16 input8 unit SXInput8Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 37 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists value 1 SXInput10Value Float Auto, -999999.0 ... 999999.0 SXInp dyna- ut10 Unit1 input10 unit SXInput10Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 38: Average Block (Ax)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP Average Block (AX) 2.4.1 Instances Instance Slot Index 2.4.2 Structure Target Mode AXTargetMode Unsigned8 Auto, 0 ... 255 non- vol. reset AXResetBlock Unsigned16 Auto, 0 ... 65535 dyna- output AXInput1Source Unsigned16 Auto,...
  • Page 39 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists value 1 AXInput2Value Float Auto, -999999.0 ... 999999.0 AXIn dyna- put2 Unit1 input2 unit AXInput2Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 40 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP input1 status AXInput4Status Unsigned8 Auto, 0 ... 255 dyna- value 1 AXInput4Value Float Auto, -999999.0 ... 999999.0 AXIn dyna- put4 Unit1 input4 unit AXInput4Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l...
  • Page 41 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists output AXInput6Source Unsigned16 Auto, 0 : none none static 30205 : level 6 input1 status AXInput6Status Unsigned8 Auto, 0 ... 255 dyna- value 1 AXInput6Value Float Auto, -999999.0 ... 999999.0 AXIn dyna-...
  • Page 42 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP level 7 AXInput7Enable OXA02 0 Unsigned8 Auto, 0 : no static 1 : yes output AXInput8Source Unsigned16 Auto, 0 : none none static 30207 : level 8 input1 status AXInput8Status Unsigned8 Auto, 0 ...
  • Page 43 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input9 unit AXInput9Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 44: Current Output Block (Co)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP Current Output Block (CO) 2.5.1 Instances Instance Slot Index 2.5.2 Structure Target Mode COTargetMode Unsigned8 Auto, 0 ... 255 non- vol. output@@ COTagNumber32 VisibleString Auto, ------------ static ------------ -------- output COInputSource Unsigned16 Auto,...
  • Page 45 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists customer unit COCustomerUnit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 46 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP turn down COTurnDownAt20mA Float Auto, COERMinTurnDownValue 100.000 static 20mA ... COERMaxTurnDownVa- usto- merU nit16 4mA threshold CO4mACutOff Unsigned8 Auto, 0 : off static 1 : on output@@ COOnStatusBad Unsigned8 Auto, 0 : min...
  • Page 47: Transducer Block (Tb)

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists Transducer Block (TB) 2.6.1 Instances Instance Slot Index 2.6.2 Structure Target Mode TBTargetMode Unsigned8 Auto, 0 ... 255 non- vol. Endress + Hauser...
  • Page 48 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP allocation TBInputSource1 Unsigned16 Auto, 0 : none none static 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5 30205 : level 6...
  • Page 49 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists customer unit TBUnit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 50: Analog Input Block (Ai)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP Analog Input Block (AI) 2.7.1 Instances Instance Slot Index 2.7.2 Structure value AIOutValue OXA02 0 Float Auto, -999999.00000 ... 0.00000 dyna- 999999.00000 status AIOutStatus OXA02 0 Unsigned8 Auto, 0 ... 255 dyna-...
  • Page 51 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists failsafe value AIFsafeValue Float Auto, -999999.00000 ... 0.00000 static 999999.00000 hysteresis AIAlarmHys Float Auto, -999999.00000 ... 0.00000 static 999999.00000 Hi Hi lim AIHiHiLim Float Auto, -999999.00000 ... 999999.0 static 999999.00000 0000 Hi lim...
  • Page 52 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP measured AIInputSource OXA02 0 Unsigned16 Auto, 0 : none none static value@@ 30200 : level 1 30201 : level 2 30202 : level 3 30203 : level 4 30204 : level 5...
  • Page 53: System Block (Sy)

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists System Block (SY) 2.8.1 Instances Instance Slot Index 2.8.2 Structure Target Mode SYTargetMode Unsigned8 Auto, 0 ... 255 non- vol. sync delay SYSynchronisationDelay_m S0040 Unsigned16 Auto, 0 ... 65000 static sync alarm...
  • Page 54: External Temperature Block (Xt)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP External Temperature Block (XT) 2.9.1 Instances Instance Slot Index 2.9.2 Structure Target Mode XTTargetMode Unsigned8 Auto, 0 ... 255 non- vol. sensor type XTInput Unsigned8 Auto, 0 : no sensor no sensor...
  • Page 55 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists output value XTExternalRawTempValue Float Auto, -999999.0 ... 999999.0 XTTe dyna- mpe- rature Unit1 Endress + Hauser...
  • Page 56: Binary Input Block (Bi)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP 2.10 Binary Input Block (BI) 2.10.1 Instances Instance Slot Index 2.10.2 Structure Target Mode BITargetMode Unsigned8 Auto, 0 ... 255 non- vol. invert BIInverting Unsigned8 Auto, 0 : no non- 1 : yes vol.
  • Page 57: Ug Block (Ug)

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists 2.11 UG Block (UG) 2.11.1 Instances Instance Slot Index 2.11.2 Structure Target Mode UGTargetMode Unsigned8 Auto, 0 ... 255 non- vol. reset UGResetBlock Unsigned16 Auto, 0 ... 65535 dyna- Endress + Hauser...
  • Page 58: Ultrasonic Sensor Block (Us)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP 2.12 Ultrasonic Sensor Block (US) 2.12.1 Instances Instance Slot Index 2.12.2 Structure Target Mode USTargetMode Unsigned8 Auto, 0 ... 255 non- vol. sensor operation USOperationMode DX018 0 Unsigned8 Auto, 0 : on...
  • Page 59: Unsigned16 Auto

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists detected USIdentifiedSensorType LX003 Unsigned16 Auto, 0 : automatic automatic dyna- 1 : FDU80 2 : FDU80F 3 : FDU81 4 : FDU81F 5 : FDU82 6 : FDU83 7 : FDU84 8 : FDU85...
  • Page 60 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP sim distance USSimDistanceMode S0107 Unsigned8 Auto, 0 : sim. off sim. off static 1 : sim. distance sim value USSimDistanceValue_mm S0007 Float Auto, -999999.000 ... 999999.000 0.000 USDi- static stanc eUnit distance unit...
  • Page 61 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists min. value USMinMeasuredTemp_Deg S0005 Float Auto, -273.0 ... 1000.0 1000.0 USTe non- mpe- vol. rature Unit1 min/maxT reset USClearMinMaxMeasu- S0105 Unsigned8 Auto, 0 : keep keep dyna- redTemp 1 : erase 2 : reset min.
  • Page 62 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP sensor priority USPriorityLevel DX106 0 Unsigned8 Auto, 1 ... 255 static recognition man. USSensorDetectManual- Unsigned16 Auto, 0 : off dyna- Start 1 : start echo quality@@ USSSignalToNoiseRatio_dB IX129 Float Auto, -999999.0 ... 999999.0...
  • Page 63 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists echo detec. type RefineMaxPosMode S0107 Unsigned16 Auto, 0 : none flank static 1 : parablefit 2 : gravity center 3 : merg. gravity 4 : merging ratio 5 : flank parable window...
  • Page 64 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP present FEF ActFirstEchoThreshold_dB S0008 108 4 Float Auto, 0.0 ... 120.0 dyna- mapping offset MappingAdder_dB S0009 109 4 Float Auto, 0.0 ... 120.0 static map scanrate MapWindowSize_mm S0009 110 4 Float Auto, 0.000 ...
  • Page 65 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists stat.temp/recog SpecialMeasGlobalMessage 118 2 Integer16 Auto, -32767 ... 32767 dyna- service sensor USSensorDetectUseEESen- S010B 119 2 Unsigned16 Auto, 0 : no static 1 : yes serv.sen.index EESensorTableIndex S000B 120 1 Unsigned8 Auto, 0 ...
  • Page 66 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP sync. delay time USSynchronisationDelay_m 140 2 Unsigned16 Auto, 0 ... 65000 static sync alarm USSynchronisationAlarm 141 1 Unsigned8 Auto, 0 : on static 1 : off sync alarm delay USSyncAlarmDelay_ms 142 2 Unsigned16 Auto, 0 ...
  • Page 67 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists ref.dist.found RefDistanceFound_mm S0007 214 4 Float Auto, -999999.0 ... 999999.0 USDi dyna- stU- nitSer vice1 delay timer JumpDelayRemainTime_s S000E 215 4 Float Auto, 0.0 ... 999999.0 dyna- echo found EchoFoundDelayTime_s S000E 216 2 Unsigned16 Auto, 0 ...
  • Page 68: Level Block (Le)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP 2.13 Level Block (LE) 2.13.1 Instances Instance Slot Index 2.13.2 Structure Target Mode LETargetMode Unsigned8 Auto, 0 ... 255 non- vol. input LESelectSensorInput LX008 Unsigned16 Auto, 0 : no sensor no sensor...
  • Page 69 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists distance unit LESensorUnit16 Unsigned16 Auto, 1010 : m dyna- 1013 : mm 1018 : ft 1019 : inch 1211 : mA 1342 : % 1038 : l 1041 : hl 1034 : m3...
  • Page 70: Visiblestring Auto

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP value empty LELevelLow LX00C 0 Float Auto, -999999.000 ... 999999.000 0.000 LELe- static velUn it16 value full LELevelHigh LX00D 0 Float Auto, -999999.000 ... 999999.000 100000.0 LELe- static velUn it16 output status...
  • Page 71 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists max. scale LELinMaxVolume LX008 Float Auto, -999999.000 ... 999999.000 100.000 LECu static stome rUnit edit LEEdit LX00D 0 Unsigned8 Auto, 0 : read read static 240 : manual 241 : semi-automatic 3 : delete...
  • Page 72 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP input level LEInputLevelManual11 LX00C 0 Float Auto, -999999.000 ... 100000.000 0.000 LELe- static velUn it16 input level LEInputLevelManual12 LX00C 0 Float Auto, -999999.000 ... 100000.000 0.000 LELe- static velUn it16 input level...
  • Page 73 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input level LEInputLevelManual28 LX00C 0 Float Auto, -999999.000 ... 100000.000 0.000 LELe- static velUn it16 input level LEInputLevelManual29 LX00C 0 Float Auto, -999999.000 ... 100000.000 0.000 LELe- static velUn it16 input level...
  • Page 74 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP input volume LEInputVolume10 LX00C 0 101 4 Float Auto, -999999.000 ... 999999.000 0.000 LECu static stome rUnit input volume LEInputVolume11 LX00C 0 102 4 Float Auto, -999999.000 ... 999999.000 0.000 LECu static...
  • Page 75: Unsigned8 Auto

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input volume LEInputVolume23 LX00C 0 114 4 Float Auto, -999999.000 ... 999999.000 0.000 LECu static stome rUnit input volume LEInputVolume24 LX00C 0 115 4 Float Auto, -999999.000 ... 999999.000 0.000 LECu static...
  • Page 76 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP sim. level value LESimulationValueLevel LX022 129 4 Float Auto, -999999.000 ... 999999.000 0.000 LELe- non- velUn vol. it16 sim. vol. value LESimulationValueVolume LX022 130 4 Float Auto, -999999.000 ... 999999.000 0.000 LEOu...
  • Page 77: Rw Static

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input 1 LEFirstDigInputValue 142 1 Unsigned8 Auto, 0 ... 255 dyna- function LESelectFirstSwitchMode LX00D 0 143 1 Unsigned8 Auto, 0 : off static 1 : Min (0%) 2 : Max (100%) 3 : hold 4 : customer spec.
  • Page 78 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP customer unit LEOutputValueUnit16 155 2 Unsigned16 Auto, 1342 : % static 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal...
  • Page 79: Sum Block (Sv)

    Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists 2.14 Sum Block (SV) 2.14.1 Instances Instance Slot Index 2.14.2 Structure Target Mode SVTargetMode Unsigned8 Auto, 0 ... 255 non- vol. reset SVResetBlock Unsigned16 Auto, 0 ... 65535 dyna- output SVInput1Source Unsigned16 Auto,...
  • Page 80 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP input1 unit SVInput2Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 81 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists input1 unit SVInput4Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3 1036 : cm3 1043 : ft3 1048 : usgal 1049 : i gal...
  • Page 82: Average Block (Av)

    Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP 2.15 Average Block (AV) 2.15.1 Instances Instance Slot Index 2.15.2 Structure Target Mode AVTargetMode Unsigned8 Auto, 0 ... 255 non- vol. reset AVResetBlock Unsigned16 Auto, 0 ... 65535 dyna- output AVInput1Source Unsigned16 Auto,...
  • Page 83 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists value 1 AVInput2Value Float Auto, -999999.0 ... 999999.0 AVIn dyna- put2 Unit1 input1 unit AVInput2Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l 1041 : hl 1034 : m3 1035 : dm3...
  • Page 84 Slot-Index Lists Prosonic S FMU95 - PROFIBUS DP input1 status AVInput4Status Unsigned8 Auto, 0 ... 255 dyna- value 1 AVInput4Value Float Auto, -999999.0 ... 999999.0 AVIn dyna- put4 Unit1 input1 unit AVInput4Unit16 Unsigned16 Auto, 1342 : % dyna- 1038 : l...
  • Page 85 Prosonic S FMU95 - PROFIBUS DP Slot-Index Lists Endress + Hauser...
  • Page 86 www.endress.com/worldwide BA00346F/00/EN/13.12 71164429 CCS/FM 9.0 71164429...

Table of Contents