Assembling The Hardware - Motorola HT 1000 User Manual

Table of Contents

Advertisement

Assembling The
Hardware
BATTERY ELIMINATOR
Replaces the battery pack
during servicing
P/N RLN-1014A (HT/JT1000)
P/N RLN-4327A (VISAR)
RADIO
PROGRAM/TEST CABLE
RKN-4035D (HT/JT1000)
RKN-4042A (VISAR)
RLN4008
Steps to Connect the
Hardware
4
The figure below shows how to assemble the required (and optional)
equipment used to program an HT 1000, JT1000 or VISAR radio.
SMA-BNC
58-80348B33
COMPUTER INTERFACE CABLE
30-80369B71 (25 pin) or
30-80369B72 (9 pin)
RIB
1. Plug the 15-pin connector on the computer interface cable into
the RIB.
2. Connect the other end of the computer interface cable to the
asynchronous adapter on the computer. The RSS uses COM1 as the
default communications port. When both a serial port and a
modem are used, it is recommended that COM1 be used as a serial
port and COM2 be used for the modem. If COM1 cannot be used
for some reason, change the default to COM2 in the main SETUP
COMPUTER CONFIGURATION screen (F9) and save it.
3. Plug the cable on the wall-mounted power supply into the RIB and
the other end into the wall outlet (optional).
4. Plug the 25-pin connector on the program/test cable to the RIB.
Connect the round 12-pin plug on the program/test cable to the
Portable Products Test Set (RTX-4005B). This is not necessary if
radio alignment will not be performed.
5. Connect the 13-pin plastic connector on the program/test cable to
the HT/JT1000 radio or the 9-pin connector to the VISAR radio as
the case may be.
TRANSMIT
30 dB PAD
30 dB PAD
RF GENERATOR
BNC
RECEIVE
TEST SET
RTX-4005B
IBM PC (IBM PC and PS/2 compatible computer with MS-DOS version 3.1 or
asynchronous communications adapter and 512K of conventional mem
data
busy
gnd
RIB POWER SUPPLY
0180357A57 (120V) or
0180357A57 (220V) or
60-82728J01 (9V)
SERVICE MONITOR
OR COUNTER
WATTMETER
TX
AUDIO GENERATOR
RX
SINAD METER
AC VOLTMETER
RVN-4098
(3-1/2 IN.)
HT/JT1000/VISAR RSS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VisarJt1000

Table of Contents