Making Switcher Processor Gpi Output Settings - Sony MVS-8000X User Manual

Multi-format production switcher processor with ccp-8000 series center control panel volume 1
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Making Switcher Processor GPI Output Settings

1
2
3
4
5
1208
Interfacing With External Devices (Device Interface Menu)
In the Switcher >Device Interface menu, press [GPI Output].
The GPI Output menu appears.
Using any of the following methods, select the settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter
Adjustment
1
Port
Port selection
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): The trigger causes the relay contacts to be open-
circuit or drives the output high, and holds this state for the
specified pulse width.
(Falling Edge): The trigger causes the relay contacts to be shorted
or drives the output low, and holds this state for the specified
pulse width.
(Any Edge): Each time the trigger occurs, the relay contacts are
alternately closed or opened, or the output is switched between
high and low.
Status: Depending on the status, the relay contacts are closed or opened,
or the output is switched between high and low.
No Operation: The trigger has no effect on the output.
Turn the knobs to select the pulse width and timing to be set.
Knob
Parameter
Adjustment
3
Pulse Width
Pulse width
4
Timing
Output timing
a) 1: Field 1, 2: Field 2, 3: Any
When "
" is selected as the trigger polarity, there is no Pulse Width
setting. When "Status" is selected, there is no Pulse Width or Timing
setting.
In the <Source> group, select the action block.
M/E-1 to M/E-4 and P/P: Set an action for the M/E or PGM/PST bank.
Common: Set an action for error status.
Setting values
1 to 8
Setting values
1 to 60 (fields)
a)
1 to 3

Advertisement

Table of Contents
loading

Table of Contents