Download Print this page

YASKAWA CIMR-V BA0001B Quick Start Manual page 20

Compact vector control drive v1000 series; cimr-vc type

Advertisement

3 Electrical Installation
Control Circuit Terminal Functions
Type
No.
Terminal Name (Signal)
S1
Multi-
to
Multi-function digital input 1 to 6
Function
S6
Digital
Inputs
SC
Multi-function input common
RP
Pulse train input
Multi-
Function
+V
Analog input power supply
Analog/
A1
Multi-function analog input 1
Pulse
A2
Multi-function analog input 2
Inputs
AC
Frequency reference common
HC
Safe Disable Input common
Safe
H1
Safe Disable Input 1
Disable
Inputs
H2
Safe Disable Input 2
Multi-
MA
N.O. (fault)
Function
MB
N.C. output (fault)
Relay
MC
Digital output common
Output
Multi-
P1
Photocoupler output 1
Function
P2
Photocoupler output 2
PHC
PC
Photocoupler output common
Output
MP
Pulse train output
Monitor
AM
Analog monitor output
Output
AC
Monitor common
R+
Communications input (+)
MEMO-
R–
Communications input (–)
BUS/
Commun
S+
Communications output (+)
ication
S-
Communications output (–)
NOTICE: The terminals HC, H1, H2 are used for the Safe Disable function which cuts the output voltage in
less than 1 ms if at least one of the inputs H1 or H2 is opened. It is designed in accordance with the ISO/EN
13849-1, Safety Category 3, PL d, and IEC/EN 61508, SIL2. It can be utilized to perform a safe stop as
defined by the IEC/EN 61800-5-2, stop category 0. Do not remove the wire link between HC, H1, or H2
unless the Safe Disable function is used. Refer to the Technical Manual when using this function.
NOTICE: The wiring length to the terminals HC, H1 and H2 should not exceed 30 m.
EN 20
Function (Signal Level), Default Setting
Photocoupler inputs, 24 Vdc, 8 mA
Note: Drive preset to sinking mode (NPN). When using
source mode, set DIP switch S3 to "SOURCE" and use an
external 24 Vdc (±10%) power supply.
Sequence common
Response frequency: 0.5 to 32 kHz, Duty: 30 to 70%, High:
3.5 to 13.2 V, Low: 0.0 to 0.8 V, input impedance: 3 k)
+10.5 V (max allowable current 20 mA)
0 to +10 Vdc (20 k) resolution 1/1000
0/4 to 20 mA (250 ) resolution: 1/500 (A2 only)
0 V
+24 V (max 10 mA allowed)
One or both open: Drive output disabled (time from input
open to drive output switch off is less than 1 ms)
Both Closed: Normal operation
Digital relay output
30 Vdc, 10 mA to 1 A
250 Vac, 10 mA to 1 A
Digital photocoupler output
48 Vdc, 2 to 50 mA
32 kHz (max)
0 to 10 Vdc (2 mA or less), Resolution: 1/1000 (10 bit)
0 V
MEMOBUS/Modbus communication.:
RS-485 or RS-422, 115.2 kbps (max)
YASKAWA ELECTRIC TOEP C710606 15E - AC Drive V1000 - Quick Start Guide

Advertisement