6 Parameter Table
Monitor
Soft Starter Output
U1-16
(freq after accel/decel ramps)
U1-18
oPE Fault Parameter
U1-24
Pulse Input frequency
Fault Trace
U2-01
Current Fault
U2-02
Previous Fault
U2-03
Frequency Reference at Previous Fault
U2-04
Output Frequency at Previous Fault
U2-05
Output Current at Previous Fault
U2-06
Motor Speed at Previous Fault
U2-07
Output Voltage at Previous Fault
U2-08
DC Bus Voltage at Previous Fault
U2-09
Output Power at Previous Fault
U2-10
Torque Reference at Previous Fault
U2-11
Input Terminal Status at Previous Fault
U2-12
Output Terminal Status at Previous Fault
U2-13
Drive Operation Status at Previous Fault
U2-14
Cumulative Operation Time at Previous Fault
Soft-Starter Speed Reference at Previous
U2-15
Fault
U2-16
Motor q-Axis Current at Previous Fault
U2-17
Motor d-Axis Current at Previous Fault
Fault History
U3-01
Lists the most recent fault that occurred
to
through the fourth most recent fault.
U3-04
U3-05
Accumulated operation time at the most
to
recent fault through the fourth most recent
U3-08
fault.
U3-09 to
Lists the fifth most recent fault that occurred
U3-14
through the tenth most recent fault.
Accumulated operation time at fifth most
U3-15 to
recent fault through the tenth most recent
U3-20
fault.
* The following faults are not recorded in the error log:
CPF00, 01, 02, 03, UV1, and UV2.
EN 32
Description
YASKAWA ELECTRIC TOEP C710606 15E - AC Drive V1000 - Quick Start Guide
DI/DO
Sel.
Digital Input Function Selections
3
Multi-step speed reference 1
4
Multi-step speed reference 2
5
Multi-step speed reference 3
Jog frequency command (higher priority than
6
multi-step speed reference)
7
Accel/decel time selection 1
F
Not used (Set when a terminal is not used)
14
Fault reset (Reset when turned ON)
External fault; Input mode: N.O. contact /
20 to 2F
N.C. contact, Detection mode: Normal/during
operation
Digital Output Function Selections
During Run (ON: run command is ON or
0
voltage is being output)
1
Zero Speed
2
Speed Agree
6
Drive Ready
E
Fault
F
Not used
10
Minor fault (Alarm) (ON: Alarm displayed)
Description