No execution
program selected.
Contact your
administrator.
Resume failure!
Program restarts
automatically.
Execution program not selected
Problem
No user program has been selected as an execu-
tion program to be run when the power is turned
on.
If this error occurs, the BHT beeps five times
(for 0.1 second per beep) and then turns itself
off.
Solution
Run System Mode and select an execution pro-
gram in the SET SYSTEM menu. (For the selecting
procedure, refer to Chapter 2, Subsection 2.6.3,
[4.1].)
Resume data saving error
Problem
When the power was turned off, the system failed
to save resume data although the resume function
had been set to ON.
The BHT displays this error message for three
seconds and automatically runs the execution
program from the point of start-up.
107