7.5 Antennas

Refer to
Section 22
for antenna information.
NOTE
GDU 45X units cannot be used with GA 35, GA 36, or GA 37 antennas.

7.6 Mounting Requirements

Refer to
Section 7.7
for outline and installation drawings.
7.6.1
Unit Installation
The GDU 45X is installed by holding the unit flush with the instrument panel and fastening the four 3/32"
hex socket head screws to the panel as shown in
7.6.2
Panel Cutout Template
The GDU 45X Nut Plate (115-01725-00) can be used as a template when marking the panel for cutout
(Figure
7-6) (dimensions on the figure are to verify accuracy of printout only). See
complete cutout dimensions. A .dxf version of the drawing is also available for download at
www.garmin.com.
190-01115-01
Rev. AC
Figure
7-4.