Trim/Flap Position Input; Trim/Flap Position Input Calibration - Garmin G3X Touch Installation Manual

Hide thumbs Also See for G3X Touch:
Table of Contents

Advertisement

34.4.26.16 Trim/Flap Position Input

The GEA 24 and GSU 73 each have multiple POS (position) inputs. Each POS input can be used with a
resistive (potentiometer) sensor to monitor the following position measurements:
Elevator Trim
Aileron Trim
Rudder Trim
Flap Position
All POS inputs require calibration (see section
NOTE
The GEA 24 POS 6 and POS 7 inputs require the LO side of the input to be connected to
ground. See
Section 29.2
Vertical Power: When using a Vertical Power unit, trim and flap positions will automatically be displayed.
Connecting, configuring, and calibrating the POS inputs is not required when the position sensors are
connected to a Vertical Power unit.

34.4.26.16.1 Trim/Flap Position Input Calibration

The process for calibrating trim/flap position inputs is similar to the process described in
Section
34.4.26.25, except the raw sensor values are read directly from the position sensors instead of
being entered manually by the installer. This allows precise calibration based on moving the control
surfaces to known positions during the calibration procedure.
To calibrate trim/flap position inputs:
1. From the POS input configuration page, press the Calibrate button to display the Calibration Page.
190-01115-01
G3X/G3X Touch Install Manual - GDU 4XX Config and Post Install Checkout
Rev. AC
Section 34.4.26.16.1
for wiring details.
).
Page 34-154

Advertisement

Table of Contents
loading

Table of Contents