2. Position the control surface to match the trim position (up/left, neutral, down/right) displayed on
the calibration page, or position the flap to the desired position.
3. Note the resulting sensor value (in volts) displayed in the Sensor Value field (the sensor value
should change with each change in trim/flap position.
4. Press the Calibrate button to add a calibration point.
5. Press the Save button to store calibration data.
6. Repeat this process for each of the Trim/Flap Positions.
NOTE
Flap position values (up to 8) should coincide with the angle of the flap position as
expressed in degrees (-90° – +90°) or percent (-100% to +100%).
To delete a calibration value, highlight the desired data in the list, and press the Delete button.
190-01115-01
G3X/G3X Touch Install Manual - GDU 4XX Config and Post Install Checkout
Rev. AC
Page 34-155