10. Go to the AP page in configuration mode and navigate to the Pitch Servo sub-section to configure
the servo direction.
a) The Servo Direction should be set to Normal. The servo arm should move clockwise to
cause a nose down elevator movement and the servo arm should move counterclockwise to
cause a nose up elevator movement.
NOSE UP
b) The Servo Direction should be set to Reverse and the servo arm should move clockwise to
cause a nose up elevator movement and the servo arm should move counterclockwise to
cause a nose down elevator movement.
NOSE DOWN
190-01115-01 G3X/G3X Touch Installation Manual - GDU 37X Config and Post Install Checkout
Rev. AC
NOSE DOWN
Figure 33-7 Normal Pitch Servo Direction
NOSE UP
Figure 33-8 Reversed Pitch Servo Direction
Page 33-45