Garmin G3X Touch Installation Manual page 89

Hide thumbs Also See for G3X Touch:
Table of Contents

Advertisement

GDU 46X Panel Cutout Drawing
IMPORTANT!
Ensure the Page Scaling setting
is set to NONE when printing
this page. Verify dimensions
of printed template are
accurate before cutting panel.
For corner holes, center punch and drill
(#36) / tap (6/32) to create threaded holes
drill out with #25 drill bit and use Garmin
nut-plate P/N 115-01725-01.
The outline in this drawing is identical
to the outline of the actual bezel.
190-01115-01
Revision AC
OR
.29 in
.29 in
7.35 mm (4X)
7.35 mm
Cut out panel
to inside line
7.29 in
7.29 in
185.10 mm
185.10 mm
10.31 in
10.31 in
262.00 mm
262.00 mm
(4X)
.29 in
.29 in
R7.35 mm (4X)
R7.35 mm
.29 in
.29 in
7.35 mm (4X)
7.35 mm
Figure 8-6 GDU 46X Panel Cutout Drawing
G3X Installation Manual - GDU 46X Installation
(4X)
(4X)
Page 8-8