Fault Reset Methods - YASKAWA Z1000 User Manual

Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

5.9 Diagnosing and Resetting Faults
u

Fault Reset Methods

When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the different
ways to restart the drive.
After the Fault Occurs
Fix the cause of the fault, restart the drive, and
reset the fault.
Resetting via Fault Reset Digital Input S4
Turn off the main power supply if the above methods do not reset the fault. Reapply power after the
HOA keypad display has turned off.
When an "SC" error occurs, contact Yaskawa or a Yaskawa agent before cycling the power to the drive.
Note:
If the Run command is present, the drive will disregard any attempts to reset the fault. Remove the Run command before attempting to clear
a fault situation.
236
Press
on the HOA keypad when the error code
is displayed.
Close then open the fault signal digital input via
terminal S4. S4 is set for "Fault Reset" as default
(H1-04 = 14).
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Procedure
Fault Reset Switch
ON
2
OFF
1
DIGITAL OPERATOR JVOP-183
ALM
-DRIVE-
-Rdy-
Freq Ref (OPR)
U1- 01=60.00Hz
----------------
U1- 02=60.00Hz
JOG FWD FWD/REV
F1
F2
M
M
ESC
HAND
RESET
ENTER
AUTO
OFF
Drive
S4 Fault Reset Digital Input
SC Digital Input Common