Command devices
Stop button (N.C. contact.). Gate stop button that excludes the automatic
closing cycle, to resume movement press the command button or use
another command device.
N.B.: if contact is unused, select 0 (Deactivated) from the F 1
function.
Opening device (N.O. contact)
Device for partial or pedestrian opening (N.O. contact).
Command for opening a leaf for pedestrian passages.
Closing device (N.O. contact)
Command device (N.O. contact). Commands for opening
and closing the gate, see feature F 7.
(N.O.) contact. for command device
(Transponder or card reader with
R700 board).
(N.O.) contact. for command
device (keypad selector with
R800 board).
Antenna with RG58 cable for
remote controls.
N.B.: insert the R800
decoding board to have
the S6000/S7000 keypad
selector recognised.
Red
Black
M E
C A
White
Blue
AF remote control card.
N.B.: plug in the (R700) coding card
for the (TSP00) sensor or the (LT001)
card reader to be recognised.