Daikin EBLQ05+07CAV3 Installer's Reference Manual page 116

Altherma low temperature monobloc
Table of Contents

Advertisement

4/8
Field settings table
Breadcrumb
Field code
Setting name
A.3.2.3
[2-09]
Ext. room sensor offset
A.3.2.4
Room temp. step
└─ Operation range
A.3.3.1
[4-02]
Space heating OFF temp
A.3.3.2
[F-01]
Space cooling On temp
└─ Domestic hot water (DHW)
└─ Type
A.4.1
[6-0D]
└─ Disinfection
A.4.4.1
[2-01]
Disinfection
A.4.4.2
[2-00]
Operation day
A.4.4.3
[2-02]
Start time
A.4.4.4
[2-03]
Temperature target
Duration
A.4.4.5
[2-04]
└─ Maximum setpoint
A.4.5
[6-0E]
└─ SP mode
A.4.6
└─ Weather dependent curve
A.4.7
[0-0B]
Weather-dependent curve
A.4.7
[0-0C]
Weather-dependent curve
A.4.7
[0-0D]
Weather-dependent curve
A.4.7
[0-0E]
Weather-dependent curve
└─ Heat sources
└─ Backup heater
A.5.1.1
[4-00]
Operation mode
A.5.1.2
Emergency
A.5.1.3
[4-07]
Enable BUH step 2
A.5.1.4
[5-01]
Equilibrium temp.
└─ System operation
└─ Auto restart
A.6.1
[3-00]
└─ Preferential kWh rate
A.6.2.1
[D-00]
Allowed heaters
A.6.2.2
[D-05]
Forced pump OFF
└─ Pwr consumpt. Control
A.6.3.1
[4-08]
Mode
A.6.3.2
[4-09]
Type
A.6.3.3
[5-05]
Amp. value
A.6.3.4
[5-09]
kW value
A.6.3.5.1
[5-05]
Amp. limits for DI
A.6.3.5.2
[5-06]
Amp. limits for DI
A.6.3.5.3
[5-07]
Amp. limits for DI
A.6.3.5.4
[5-08]
Amp. limits for DI
A.6.3.6.1
[5-09]
kW limits for DI
A.6.3.6.2
[5-0A]
kW limits for DI
A.6.3.6.3
[5-0B]
kW limits for DI
A.6.3.6.4
[5-0C]
kW limits for DI
A.6.3.7
[4-01]
Priority
└─ Averaging time
A.6.4
[1-0A]
└─ Ext amb. sensor offset
A.6.5
[2-0B]
└─ Boiler efficiency
4P405542-1 - 2015.03
Leaving water value for high ambient temp. for
DHW WD curve.
Leaving water value for low ambient temp. for
DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Limit DI1
Limit DI2
Limit DI3
Limit DI4
Limit DI1
Limit DI2
Limit DI3
Limit DI4
Range, step
Default value
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: 0,5 °C
1: 1 °C
R/W
14~35 °C, step: 1°C
25°C
R/W
10~35°C, step: 1°C
20°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
0: No
1: Yes
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0~23 hour, step: 1 hour
23
R/W
55~80°C, step: 5°C
70°C
R/W
5~60 min, step: 5 min
10 min
R/W
40~80°C, step: 1°C
60°C
R/W
0: Fixed
1: Weather dep.
R/W
35~[6-0E]°C, step: 1°C
55°C
R/W
45~[6-0E]°C, step: 1°C
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
0~2
0: Disabled
1: Enabled
R/W
0: Manual
1: Automatic
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
-4°C
R/W
0: No
1: Yes
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
R/W
0: Forced off
1: As normal
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0: None
1: BSH
2: BUH
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
R/W
-5~5°C, step: 0,5°C
0°C
Installer setting at variance with
default value
Date
Value
(*1) *B*_(*2) *D*