Installation manual
Daikin Altherma low temperature monobloc option
box
Installation manual
English
Daikin Altherma low temperature monobloc option box
EK2CB07CAV3

Advertisement

loading

Summary of Contents for Daikin EK2CB07CAV3

  • Page 1 Installation manual Daikin Altherma low temperature monobloc option Installation manual English Daikin Altherma low temperature monobloc option box EK2CB07CAV3...
  • Page 2: About The Box

    Format General Safety instructions that Paper (in the box of the safety you must read before outdoor unit) precautions installing Connectors for interconnection cable between the option box and control box EKCB07CAV3. Outdoor unit Installation instructions Paper (in the box of the installation outdoor unit) manual Control box Installation instructions Paper (in the box of the installation control box) manual Option box Installation instructions Paper (in the box of the installation option box) manual Backup Installation instructions Paper (in the box of the heater backup heater) installation manual Installation manual EK2CB07CAV3 Daikin Altherma low temperature monobloc option box 4P405546­1 – 2015.03...
  • Page 3: Installation

    318 mm ON/OFF output Changeover to external 3 Drill 4 holes and install 4 plugs (suitable for M5). heat source 4 Put  the  screws  in  the  top  plugs  and  hang  the  box  on  the Cable section 2.5 mm². screws. Minimum cable section 0.75 mm². 5 Put the screws in the bottom plugs. NOTICE 6 Fix the 4 screws firmly. More  technical  specifications  of  the  different  connections are indicated on the inside of the option box. EK2CB07CAV3 Installation manual Daikin Altherma low temperature monobloc option box 4P405546­1 – 2015.03...
  • Page 4 1 Connect the electrical meters cable to the appropriate terminals as shown in the illustration below. NOTICE The  distance  between  the  high  voltage  and  low  voltage cables should be at least 25 mm. 4.3.3 To connect the option box power supply 1 Connect option box terminal X1M to control box terminal X1M. S5P S6P 2 Fix the cable with cable ties to the cable tie mountings. 2 Fix  the  cable  with  cable  ties  to  the  cable  tie  mountings  to ensure strain relief and to make sure that it does NOT come in contact with sharp edges. Installation manual EK2CB07CAV3 Daikin Altherma low temperature monobloc option box 4P405546­1 – 2015.03...
  • Page 5: Starting Up The System

    2 Fix the cable with cable ties to the cable tie mountings. 4.3.7 To connect the alarm output 1 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. 2 Fix the cable with cable ties to the cable tie mountings. Starting up the system For  instructions  on  how  to  configure  and  commission  the  system, and  hand  it  over  to  the  user,  refer  to  the  installation  manual  of  the outdoor unit. 2 Fix the cable with cable ties to the cable tie mountings. EK2CB07CAV3 Installation manual Daikin Altherma low temperature monobloc option box 4P405546­1 – 2015.03...