Daikin EBLQ05+07CAV3 Installer's Reference Manual page 107

Altherma low temperature monobloc
Table of Contents

Advertisement

Outdoor units
Nominal running current
Starting current
Maximum running current
Z
max
Minimum S
value
sc
Recommended fuses
Wiring connections
For power supply
For connection with control box
Figure A: Starting current
Daikin inverter controlled compressor starting current always less
than or equal to maximal running current.
A
C
D
E
A
Running current
B
Time
C
Maximum
D
Example 1
E
Example 2
Standard on/off compressor starting current to maximum running
current
A
C
D
E
A
Running current
B
Time
C
Maximum
D
Example 1
E
Example 2
(3) European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤75 A
per phase.
EBLQ05+07CAV3 + EDLQ05+07CAV3 + EKCB07CAV3 +
EK2CB07CAV3 + EKMBUHCA3V3 + EKMBUHCA9W1
Daikin Altherma low temperature monobloc
4P405544-1 – 2015.03
Cooling
Heating
Cooling
Heating
Cooling
Heating
Quantity
Remark
Quantity
Remark
B
B
EDLQ05CAV3
EDLQ07CAV3
15.7 A
18.0 A (see
Figure A)
15.7 A
18.0 A (see
Figure A)
Equipment complying with EN/IEC 61000‑3‑12
16 A
20 A
2 wires: minimum cable section 0.75 mm², maximum length: 20 m; 2
wires: minimum cable section 0.75 mm², maximum length: 500 m; 4
wires: 230 V
14 Technical data
EBLQ05CAV3
EBLQ07CAV3
15.7 A
18.0 A (see
Figure A)
15.7 A
18.0 A (see
Figure A)
(3)
16 A
20 A
3
8
Installer reference guide
107