Field settings table
Breadcrumb
Field code
Setting name
A.2.1.B
User interface location
A.2.1.C
[E-0D]
Glycol present
└─ Options
A.2.2.A
[D-02]
DHW pump
A.2.2.B
[C-08]
External sensor
└────────────────── Control box
A.2.2.E.1
[E-03]
Backup heater steps
A.2.2.E.2
[5-0D]
BUH type
A.2.2.E.3
[D-01]
Preferential kWh rate
A.2.2.E.4
[E-05]
DHW operation
A.2.2.E.5
[C-05]
Contact type main
A.2.2.E.6
[C-06]
Contact type add.
└────────────────── Option box
A.2.2.F.1
[C-02]
Ext. backup heat src
A.2.2.F.2
[C-09]
Alarm output
A.2.2.F.3
[D-08]
External kWh meter 1
A.2.2.F.4
[D-09]
External kWh meter 2
A.2.2.F.5
[C-08]
External sensor
A.2.2.F.6
[D-04]
PCC by digital inputs
└─ Capacities
A.2.3.1
[6-02]
Booster heater
A.2.3.2
[6-03]
BUH: step 1
A.2.3.3
[6-04]
BUH: step 2
Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.2.3
[9-03]
Temperature range
A.3.1.1.2.4
[9-02]
Temperature range
A.3.1.1.5
[8-05]
Modulated LWT
A.3.1.1.7
[9-0B]
Emitter type
└────────────────── Additional
A.3.1.2.1
LWT setpoint mode
A.3.1.2.2.1
[9-05]
Temperature range
A.3.1.2.2.2
[9-06]
Temperature range
A.3.1.2.2.3
[9-07]
Temperature range
A.3.1.2.2.4
[9-08]
Temperature range
└────────────────── Delta T source
A.3.1.3.1
[9-09]
Heating
A.3.1.3.2
[9-0A]
Cooling
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
A.3.2.1.2
[3-06]
Room temp. range
A.3.2.1.3
[3-09]
Room temp. range
A.3.2.1.4
[3-08]
Room temp. range
A.3.2.2
[2-0A]
Room temp. offset
(*1) *B*_(*2) *D*
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Range, step
Default value
R/W
0: At unit
1: In room
R/W
0: No
1: Yes
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: No BUH
1: 1 step
2: 2 steps
R/W
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2)
R/W
0: No
1: Active open
2: Active closed
R/W
0: No
1: Yes
R/W
1: Thermo ON/OFF
2: C/H request
R/W
0~2
1: Thermo ON/OFF
R/W
0: No
1: Bivalent
2: -
3: -
R/W
0: Normally open
1: Normally closed
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: No
1: Yes
R/W
0~10kW, step: 0,2kW
3kW
R/W
0~10kW, step: 0,2kW
3kW
R/W
0~10kW, step: 0,2kW
0kW
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~55°C, step: 1°C
55°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
0: No
1: Yes
R/W
0: Quick
1: Slow
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~55°C, step: 1°C
55°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
3~10°C, step: 1°C
5°C
R/W
3~10°C, step: 1°C
5°C
R/W
12~18°C, step: A.3.2.4
16°C
R/W
18~30°C, step: A.3.2.4
30°C
R/W
15~25°C, step: A.3.2.4
15°C
R/W
25~35°C, step: A.3.2.4
35°C
R/W
-5~5°C, step: 0,5°C
0°C
3/8
Installer setting at variance with
default value
Date
Value
4P405542-1 - 2015.03