Daikin Altherma EBLQ05CAV3 User Reference Manual

Daikin Altherma EBLQ05CAV3 User Reference Manual

Low temperature monobloc
Hide thumbs Also See for Altherma EBLQ05CAV3:
Table of Contents

Advertisement

User reference guide
Daikin Altherma low temperature monobloc
EBLQ05+07CAV3
EDLQ05+07CAV3
EKCB07CAV3
EK2CB07CAV3
User reference guide
EKMBUHCA3V3
English
Daikin Altherma low temperature monobloc
EKMBUHCA9W1

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Altherma EBLQ05CAV3

  • Page 1 User reference guide Daikin Altherma low temperature monobloc EBLQ05+07CAV3 EDLQ05+07CAV3 EKCB07CAV3 EK2CB07CAV3 User reference guide EKMBUHCA3V3 English Daikin Altherma low temperature monobloc EKMBUHCA9W1...
  • Page 2: Table Of Contents

    Indicates a situation that could result in explosion. 4.7.6 Predefined schedules: DHW tank temperature... 18 Weather dependent operation........... 18 4.8.1 To set the weather dependent settings....... 18 Menu structure: Overview user settings ........20 User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 3: For The User

    Latest revisions of the supplied documentation may be available on ▪ Do NOT place any objects or equipment on top of the the regional Daikin website or via your installer. unit. The original documentation is written in English. All other languages ▪...
  • Page 4: About The System

    ▪ Changes settings. Domestic hot water How to control domestic hot water: ▪ Selects a mode. control ▪ Reheat mode ▪ Scheduled mode ▪ Scheduled + reheat mode User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 5: Status Icons

    Main (+ additional) leaving water temperature control is Emergency operation is active. automatically turned ON. Main (+ additional) leaving water Room temperature control is temperature control NOT automatically turned ON. EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 6: Space Heating/Cooling Control

    1 Go to [7.5]: > User settings > Allowed operation mode. following: 2 Select a month and press 3 Select Heating only, Cooling only or Heating/Cooling, and press User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 7: Determining Which Temperature Control You Are Using

    Else Leaving water temperature control. 3 Only for room thermostat control: Go to the main leaving water temperature home page (LWT main) and check the following: EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 8: Room Thermostat Control - Using The Room Temperature Home Page

    AND changing the mode to preset value The next scheduled action is at 17:00 and the desired You have configured the following settings: temperature will then increase. User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 9: Room Thermostat Control - Using The Leaving Water Temperature Home

    Result: For the next 2  hours, the room will NOT be heated to the scheduled 20°C, but to the preset value (Eco = 18°C). After 2 hours, the room will heat up again to the scheduled 20°C. EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 10: Leaving Water Temperature Control - About Leaving Water Temperature Control

    To control the leaving water temperature, To adjust the leaving water temperature you can do the following: (additional) 1 Go to the additional leaving water temperature home page (LWT add). User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 11: External Room Thermostat Control - About External Room Thermostat Control

    ▪ Room temperature on the external thermostat control disinfection function occurred due to domestic hot water ▪ Leaving water temperature on the user interface (Daikin) tapping, following actions are recommended: ▪ When the Domestic hot water > Type > Reheat or Reheat + sched.
  • Page 12: Scheduled Mode

    ▪ At 14:00 the DHW tank is programmed to heat up the water to a You can… Location preset value (example: Storage eco = 50°C). Hot water is Do the same things as in scheduled mode. — available again. User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 13: Using The Dhw Tank Temperature Home Page

    ▪ Next scheduled action of the DHW  tank = Heat up to the preset 2 Press for more than 4 seconds. value (Eco; example: 55°C and sufficient for 2 persons) at 14:00 EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 14: Using Quiet Mode

    ▪ Program a schedule. See 2 Check the following: "4.7.2  Using programming schedules"  on page 17. Usage example: Baby is sleeping in the afternoon If you are in the following situation: User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 15: Reading Out Information

    Example: Domestic hot water pump ON/OFF. Prerequisite: You have configured the holiday. 1 Go to [2.1]: > Holiday > Holiday. 2 Do one of the following: EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 16: Configuring Date, Time, Units Of Measurement, Contrast And Backlight

    On If user profile = Detailed, you can see and do more on the home Elec price High Not applicable pages. Medium Fuel price Not applicable User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 17: Using And Programming Schedules

    1 Go to [7.3]: > User settings > Set schedules. 1 Press , select Save schedule and press 2 Open an empty, predefined or user‑defined schedule. EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 18: Predefined Schedules: Room Temperature + Leaving Water Temperature (Main)

    INFORMATION The predefined schedules are applicable for both heating Target leaving water temperature and cooling operation. Outdoor temperature Low outdoor ambient temperature High outdoor ambient temperature User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 19 (c) as for high outdoor temperatures less warm water is required. In cooling, this value should be lower than (c) as for high outdoor temperatures colder water is required. EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 20: Menu Structure: Overview User Settings

    Set weather-dependent heating Set weather-dependent cooling [7.7.2] Additional Set weather-dependent heating Set weather-dependent cooling INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 21: Installer Settings: Tables To Be Filled In By Installer

    Low, according to your electricity tariff. Setting Default Fill in… 3 Press to confirm. Type 1 (R+S) INFORMATION Maximum setpoint 60°C Price value ranging from 0.00~990  valuta/kWh (with 2 significant values). EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 22: To Set The Electricity Price Schedule Timer

    The installer has to perform a yearly maintenance. You can find the Calculation of the electricity price: contact/helpdesk number via the user interface. Electricity price=Actual electricity price+incentive/kWh As end user, you have to: User reference guide EBLQ05+07CAV3 + EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 23: To Find The Contact/Helpdesk Number

    Prerequisite: Only available if is displayed on the home pages. 1 Go to [6.3.1]: > Information > Error handling > Warning history. EBLQ05+07CAV3 + EDLQ05+07CAV3 User reference guide Daikin Altherma low temperature monobloc 4P405545-1C – 2018.06...
  • Page 24: Relocation

    INFORMATION the accompanying documentation. When the backup heater or booster heater takes over the Field supply heat load, electricity consumption will be considerably Equipment NOT made by Daikin that can be combined with higher. product according instructions accompanying documentation.
  • Page 28 4P405545-1C 2018.06...

Table of Contents