Daikin EBLQ05+07CAV3 Installer's Reference Manual page 114

Altherma low temperature monobloc
Table of Contents

Advertisement

2/8
Field settings table
Breadcrumb
Field code
Setting name
User settings
└─ Preset values
└─ Room temperature
7.4.1.1
Comfort (heating)
7.4.1.2
Eco (heating)
7.4.1.3
Comfort (cooling)
7.4.1.4
Eco (cooling)
└─ LWT main
7.4.2.1
[8-09]
Comfort (heating)
7.4.2.2
[8-0A]
Eco (heating)
7.4.2.3
[8-07]
Comfort (cooling)
7.4.2.4
[8-08]
Eco (cooling)
7.4.2.5
Comfort (heating)
7.4.2.6
Eco (heating)
7.4.2.7
Comfort (cooling)
7.4.2.8
Eco (cooling)
└─ Tank temperature
Storage comfort
7.4.3.1
[6-0A]
7.4.3.2
[6-0B]
Storage eco
7.4.3.3
[6-0C]
Reheat
└─ Quiet level
7.4.4
└─ Electricity price
7.4.5.1
[C-0C]
High
[D-0C]
7.4.5.2
[C-0D]
Medium
[D-0D]
7.4.5.3
[C-0E]
Low
[D-0E]
└─ Fuel price
7.4.6
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
7.7.1.1
[1-01]
Set weather-dependent heating
7.7.1.1
[1-02]
Set weather-dependent heating
7.7.1.1
[1-03]
Set weather-dependent heating
└────────────────── Set weather-dependent cooling
7.7.1.2
[1-06]
Set weather-dependent cooling
7.7.1.2
[1-07]
Set weather-dependent cooling
7.7.1.2
[1-08]
Set weather-dependent cooling
7.7.1.2
[1-09]
Set weather-dependent cooling
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1
[0-00]
Set weather-dependent heating
7.7.2.1
[0-01]
Set weather-dependent heating
7.7.2.1
[0-02]
Set weather-dependent heating
7.7.2.1
[0-03]
Set weather-dependent heating
└────────────────── Set weather-dependent cooling
7.7.2.2
[0-04]
Set weather-dependent cooling
7.7.2.2
[0-05]
Set weather-dependent cooling
7.7.2.2
[0-06]
Set weather-dependent cooling
7.7.2.2
[0-07]
Set weather-dependent cooling
Installer settings
└─ System layout
└─ Standard
A.2.1.1
[E-00]
Unit type
A.2.1.2
[E-01]
Compressor type
A.2.1.3
[E-02]
Indoor software type
A.2.1.7
[C-07]
Unit control method
A.2.1.8
[7-02]
Number of LWT zones
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.A
[E-04]
Power saving possible
4P405542-1 - 2015.03
Low ambient temp. for LWT main zone heating
WD curve.
High ambient temp. for LWT main zone heating
WD curve.
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
Low ambient temp. for LWT main zone cooling
WD curve.
High ambient temp. for LWT main zone cooling
WD curve.
Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating
WD curve.
Low ambient temp. for LWT add zone heating
WD curve.
Leaving water value for high ambient temp. for
LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for
LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling
WD curve.
Low ambient temp. for LWT add zone cooling
WD curve.
Range, step
Default value
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
R/W
[3-08]~[3-09], step: A.3.2.4
24°C
R/W
[3-08]~[3-09], step: A.3.2.4
26°C
R/W
[9-01]~[9-00], step: 1°C
45°C
R/W
[9-01]~[9-00], step: 1°C
40°C
R/W
[9-03]~[9-02], step: 1°C
18°C
R/W
[9-03]~[9-02], step: 1°C
20°C
R/W
-10~10°C, step: 1°C
0°C
R/W
-10~10°C, step: 1°C
-2°C
R/W
-10~10°C, step: 1°C
0°C
R/W
-10~10°C, step: 1°C
2°C
R/W
30~[6-0E]°C, step: 1°C
55°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: Level 1
1: Level 2
2: Level 3
R/W
0,00~990/kWh
0/kWh
R/W
0,00~990/kWh
0/kWh
R/W
0,00~990/kWh
0/kWh
R/W
0,00~990/kWh
0,00~290/MBtu
8,0/kWh
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-01]~[9-00]°C, step: 1°C
45°C
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
35°C
R/W
10~25°C, step: 1°C
20°C
R/W
25~43°C, step: 1°C
35°C
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
R/W
[9-05]~[9-06]°C, step: 1°C
45°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
[9-07]~[9-08]°C, step: 1°C
8°C
R/W
[9-07]~[9-08]°C, step: 1°C
12°C
R/W
25~43°C, step: 1°C
35°C
R/W
10~25°C, step: 1°C
20°C
R/O
0~5
2: Monobloc
R/O
0~1
0: 8
R/O
0: Type 1 (*1)
1: Type 2 (*2)
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0: Continuous
1: Sample
2: Request
R/O
0: No
1: Yes
Installer setting at variance with
default value
Date
Value
(*1) *B*_(*2) *D*

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents