Environmental Type Tests - Siemens RUGGEDCOM RMC40 Installation Manual

4-port unmanaged ethernet switch
Hide thumbs Also See for RUGGEDCOM RMC40:
Table of Contents

Advertisement

RUGGEDCOM RMC40
Installation Guide
HV Impulse
Dielectric Strength

Environmental Type Tests

Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
EMC and Environmental Type Tests
Description
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Description
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
2.5 kV common, 1 kV differential mode @ 1MHz
2.5 kV common, 1 kV differential mode @ 1MHz
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10-150 Hz
30 g @ 11 ms
Certification
Test Levels
5 kV (Failsafe Relay)
5 kV
5 kV
2 kV
1.5 kV
2 kV
Severity Levels
Class 2
Class 2
Chapter 6