Siemens RUGGEDCOM RMC40 Installation Manual

Siemens RUGGEDCOM RMC40 Installation Manual

Simatic net rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RMC40:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RMC40
Edition
04/2021
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RMC40

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RMC40 Edition 04/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Communication Ports Rugged Ethernet Switches RUGGEDCOM RMC40 Technical Specifications Certification Installation Manual 04/2021 C79000-G8976-1009-09...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ........................ vi Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Supported Fiber Optic Cables ................
  • Page 5 FCC ........................22 5.1.4 FDA/CDRH ......................22 5.1.5 ISED ........................22 5.1.6 ISO ........................22 5.1.7 ACMA ........................23 5.1.8 RoHS ........................23 5.1.9 Other Approvals ....................23 EMC and Environmental Type Tests ..............24 RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8 Preface Contacting Siemens 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7 Telephone Toll-free: 1 888 264 0006 Tel: +1 905 856 5288 Fax: +1 905 856 1995 E-Mail ruggedcom.info.i-ia@siemens.com https://www.siemens.com RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 10: Introduction

    Ethernet networking applications. The RUGGEDCOM RMC40 is packaged in a compact, galvanized steel enclosure that allows either DIN or panel mounting for efficient use of cabinet space. It has an integrated power supply with a wide range of voltages for worldwide operability.
  • Page 11: Description

    Description The RUGGEDCOM RMC40 features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 12: Required Tools And Materials

    RUGGEDCOM RMC40, refer to "Communication Ports (Page 13)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RMC40: Tools/Materials Purpose AC or DC power cord (16 AWG) For connecting power to the device.
  • Page 13: Supported Fiber Optic Cables

    1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) — 1300 2000 — — OM3 (50/125) 1500 — 1300 2000 — — OM4 (50/125) 3500 — 1300 2000 — — Laser optimized. RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: General Procedure

    If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RMC40 is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be attached to a DIN rail or panel.
  • Page 16: Mounting The Device On A Din Rail

    2.3.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RMC40 can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
  • Page 17 Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail Swing the bottom of the device away from the DIN rail. Lift the device off the DIN rail. RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 18: 2.3.2 Mounting The Device To A Panel

    Insert the device into the adapter. Make sure the device is secured between the two metal clips. Install the screw previously removed from the bottom of the panel adapter. Connecting Power The RUGGEDCOM RMC40 supports a single integrated high AC/DC or low DC power supply RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 19: 2.4.1 Connecting Ac Power

    Note Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than that for which the device is rated. Use the following specifications as a guide for VDSL external surge protection: •...
  • Page 20 The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit. Connect the ground terminal on the power source to the chassis ground terminal on the device. RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 21: 2.4.2 Connecting Dc Power

    The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit. Connect the ground terminal on the power source to the chassis ground terminal on the device. RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 22: Communication Ports

    Communication Ports The RUGGEDCOM RMC40 can be equipped with various types of communication ports to enhance its abilities and performance. Port 1 Port 2 Port 3 Port 4 Figure 3.1 Port Assignment Port Type Copper Ethernet Port Copper Ethernet Port 3 to 4...
  • Page 23 RJ45 Ethernet Port Pin Reserved (Do Not Connect) Configuration Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Specifications For specifications on the available copper Ethernet ports, refer to "Copper Ethernet Port Specifications (Page 17)". RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 24: Fiber Optic Ethernet Ports

      Tx Connector Tx Connector Rx Connector Rx Connector Figure 3.5 SC Port Figure 3.6 ST Port Specifications For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications (Page 17)". RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 25 Communication Ports 3.2 Fiber Optic Ethernet Ports RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 26: Technical Specifications

    Typical distance. Dependent on the number of connectors and splices. RMS 1 minute. Fiber Optic Ethernet Port Specifications The following details the specifications for fiber optic Ethernet ports that can be ordered with the RUGGEDCOM RMC40. RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 27: Supported Networking Standards

    3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens Sales associate when determining maximum segment distances. Data...
  • Page 28: Operating Environment

    Mechanical Specifications Weight 0.68 kg (1.5 lbs) Ingress Protection IP30 Enclosure 21 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 90.4 80.1 62.2 73.7 58.4 70.7 Figure 4.1 Overall Dimensions RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 29 Technical Specifications 4.7 Dimension Drawings 67.3 62.2 92.5 58.4 82.2 35.6 11.4 Figure 4.2 Panel Mount Dimensions RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 30: Certification

    UL 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements) 5.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment –...
  • Page 31: 5.1.3 Fcc

    Certification 5.1.3 FCC The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vi)".
  • Page 32: Acma

    A copy of the Declaration of Conformity is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 5.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 33: Emc And Environmental Type Tests

    Certification 5.2 EMC and Environmental Type Tests EMC and Environmental Type Tests The RUGGEDCOM RMC40 has passed the following EMC and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels Severity Levels Enclosure ± 8 kV 61000-4-2 Contact Enclosure Air ±...
  • Page 34 5 kV   Ports Siemens specified severity level. IEEE 1613 EMC Immunity Type Tests Note The RUGGEDCOM RMC40 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Description Test Levels Enclosure Contact ± 8 kV Enclosure Air ±...
  • Page 35 Certification 5.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60255-21-1 Vibration 2 g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2 RUGGEDCOM RMC40 Installation Manual, 04/2021, C79000-G8976-1009-09...
  • Page 36 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents