Siemens RUGGEDCOM RMC40 Installation Manual

4-port unmanaged ethernet switch
Hide thumbs Also See for RUGGEDCOM RMC40:

Advertisement

Quick Links

RUGGEDCOM RMC40
Installation Guide
08/2017
RC1009-EN-06
Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RMC40

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RMC40 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 08/2017 RC1009-EN-06...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RMC40   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 Chapter 2 Installing the Device ..................
  • Page 4   RUGGEDCOM RMC40 Table of Contents Installation Guide Chapter 5 Dimension Drawings ..................Chapter 6 Certification ....................6.1    Approvals ........................... 21 6.1.1    CSA ..........................21 6.1.2  European Union (EU) ....................... 22 6.1.3    FCC ..........................22 6.1.4  FDA/CDRH ........................22 6.1.5 ...
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RMC40. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    An operating temperature range of -40 to 85°C (-40 to 185°F) without the use of internal cooling fans allows it to be placed in almost any location. The RUGGEDCOM RMC40 is compliant with EMI and environmental standards for utility substations, industrial manufacturing, process and control and intelligent transportation systems applications.
  • Page 8: Description

    Section 1.2 Description The RUGGEDCOM RMC40 features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 9 A pluggable terminal. For more information, refer to: • Section 2.4, “Connecting Power” • Section 4.1, “Power Supply Specifications” Communication Ports Receive and transmit data. For more information about the various ports available for the Chapter 3, Communication Ports. RUGGEDCOM RMC40, refer to Description...
  • Page 10 Chapter 1 RUGGEDCOM RMC40 Introduction Installation Guide Description...
  • Page 11: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: Required Tools And Materials

    Section 2.3 Mounting the Device The RUGGEDCOM RMC40 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail or directly on a panel.
  • Page 13: Mounting The Device On A Din Rail

    RUGGEDCOM RMC40 Chapter 2 Installation Guide Installing the Device Section 2.3.1 Mounting the Device on a DIN Rail For DIN rail installations, the RMC40 can be equipped with a DIN rail bracket pre-installed on the back of the chassis. The bracket allows the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 14: Connecting Power

    Ground. Note that all line-to-ground transient protection circuitry will be disabled. IMPORTANT! Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than that for which the device is rated. Use the following specifications as a...
  • Page 15: Connecting Ac Power

    RUGGEDCOM RMC40 Chapter 2 Installation Guide Installing the Device • Clamping Voltage: 50 V to 200 V • Insertion Loss: < 0.1 dB at 10 MHz • Peak Surge Current: 10 kA, 8x20µs waveform CONTENTS • Section 2.4.1, “Connecting AC Power”...
  • Page 16: Connecting Dc Power

    Chapter 2 RUGGEDCOM RMC40 Installing the Device Installation Guide Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection. The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit.
  • Page 17: Communication Ports

    RUGGEDCOM RMC40 Chapter 3 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RMC40 can be equipped with various types of communication ports to enhance its abilities and performance. Figure 6: Port Assignment 1. Port 1    2. Port 2    3. Port 3    4. Port 4 Port Type...
  • Page 18: Specifications

    Chapter 3 RUGGEDCOM RMC40 Communication Ports Installation Guide WARNING! Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end.
  • Page 19: Fiber Optic Ethernet Ports

    RUGGEDCOM RMC40 Chapter 3 Installation Guide Communication Ports Section 3.2 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Registered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors. Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link.
  • Page 20 Chapter 3 RUGGEDCOM RMC40 Communication Ports Installation Guide Fiber Optic Ethernet Ports...
  • Page 21: Technical Specifications

    RUGGEDCOM RMC40 Chapter 4 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device and available modules. CONTENTS • Section 4.1, “Power Supply Specifications” • Section 4.2, “Copper Ethernet Port Specifications” • Section 4.3, “Fiber Optic Ethernet Port Specifications”...
  • Page 22: Fiber Optic Ethernet Port Specifications

    To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens Sales associate when determining maximum segment distances. Wavelength (nm)
  • Page 23: Supported Networking Standards

    RUGGEDCOM RMC40 Chapter 4 Installation Guide Technical Specifications Section 4.4 Supported Networking Standards Parameter 10Base-FL 100Base-FX Notes IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/100Base-FX IEEE 802.3x Full Duplex, Flow Control Section 4.5 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 80 °C Measured from a 30 cm (12 in) radius surrounding the center of the (-40 to 176 °F)
  • Page 24 Chapter 4 RUGGEDCOM RMC40 Technical Specifications Installation Guide Mechanical Specifications...
  • Page 25: Dimension Drawings

    RUGGEDCOM RMC40 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 90.4 80.1 73.7 62.2 58.4 70.7 Figure 12: Overall Dimensions...
  • Page 26 Chapter 5 RUGGEDCOM RMC40 Dimension Drawings Installation Guide 67.3 62.2 92.5 58.4 82.2 35.6 11.4 Figure 13: Panel Mount Dimensions...
  • Page 27: Certification

    RUGGEDCOM RMC40 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RMC40 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 28: European Union (Eu)

    Information Technology Equipment – Radio disturbance characteristics – Limits and methods of measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 29: Rohs

    • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 30 AC Power Ports 5 kV Siemens specified severity level. IEEE 1613 EMC Immunity Type Tests NOTE The RUGGEDCOM RMC40 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Description Test Levels Enclosure Contact ± 8 kV Enclosure Air ±...
  • Page 31: Environmental Type Tests

    RUGGEDCOM RMC40 Chapter 6 Installation Guide Certification Description Test Levels DC Power Ports 2.5 kV common, 1 kV differential mode @ 1MHz AC Power Ports 2.5 kV common, 1 kV differential mode @ 1MHz HV Impulse Signal Ports 5 kV (Failsafe Relay)
  • Page 32 Chapter 6 RUGGEDCOM RMC40 Certification Installation Guide EMC and Environmental Type Tests...

Table of Contents