Page 1
Preface Introduction Installing the Device RUGGEDCOM RX1100P Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 4/2015 RC1052-EN-03...
Page 2
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Installation Guide Preface Preface This guide describes the RUGGEDCOM RX1100P. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
RUGGEDCOM RX1100P Chapter 1 Installation Guide Introduction Introduction The RX1100P is an industrially hardened, Power over Ethernet (PoE) enabled, cyber security appliance with integrated router, firewall and VPN functionality. The device may be equipped with up to four 10/100Base-TX 802.3af (PoE) copmliant Ethernet ports.
Page 8
Chapter 1 RUGGEDCOM RX1100P Introduction Installation Guide • VPN with 3DES, DES and AES support • Intrusion Detection Service (IDS) • RADIUS centralized password management Rated for Reliability in Harsh Environments • Immunity to EMI and high voltage electrical transients ▪...
RUGGEDCOM RX1100P Chapter 1 Installation Guide Introduction • IP ▪ Routing: VRRP, OSPF, RIP, BGP ▪ DHCP Agent (Option 82 capable) ▪ Traffic prioritization, NTP Server, IP Multicast Routing Section 1.2 Ports, Controls and Indicator LEDs The RX1100P features various ports, controls and indicator LEDs on the front panel for configuring and troubleshooting the device.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Chapter 2 RUGGEDCOM RX1100P Installing the Device Installation Guide NOTE For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to Chapter 5, Dimension Drawings. The following sections describe the various methods of mounting the device: •...
RUGGEDCOM RX1100P Chapter 2 Installation Guide Installing the Device Section 2.1.2 Mounting the Device on a DIN Rail For DIN rail installations, the RX1100P can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
Chapter 2 RUGGEDCOM RX1100P Installing the Device Installation Guide Figure 4: Panel Mounting 1. Screw 2. Panel/DIN Rail Adaptor Install the supplied screws to secure the adapters to the panel. Section 2.2 Connecting Power The RX1100P supports single or dual redundant AC and/or DC power supplies. The use of two power modules is recommended to provide redundancy and load balancing.
RUGGEDCOM RX1100P Chapter 2 Installation Guide Installing the Device • Equipment must be installed according to applicable local wiring codes and standards. The following sections describe how to connect power to the device: • Section 2.2.1, “Connecting AC Power” •...
Chapter 2 RUGGEDCOM RX1100P Installing the Device Installation Guide Figure 5: Terminal Block Wiring 1. Screw-Type Terminal Block 2. Pluggable Terminal Block 3. Jumper 4. Positive/Live (+/L) Terminal 5. Negative/Neutral (-/N) Terminal 6. Surge Ground Terminal 7. Chassis Ground Terminal Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
Page 17
RUGGEDCOM RX1100P Chapter 2 Installation Guide Installing the Device NOTE The screw-type terminal block is installed using Philips screws and compression plates, allowing either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable screws, which must be removed to make connections.
Chapter 2 RUGGEDCOM RX1100P Installing the Device Installation Guide Section 2.2.3 Wiring Examples The following illustrate how to connect power to single and dual power supplies. Figure 7: Single AC Power Supply Figure 8: Single DC Power Supply Wiring Examples...
Page 19
RUGGEDCOM RX1100P Chapter 2 Installation Guide Installing the Device Figure 9: Dual AC/DC Power Supply Figure 10: Dual DC Power Supply Wiring Examples...
Chapter 2 RUGGEDCOM RX1100P Installing the Device Installation Guide Figure 11: Dual AC/DC or AC and 48 V PoE Power Supply Section 2.3 Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
Section 2.5 Cabling Recommendations Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
Installing the Device Installation Guide Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports Communication Ports The RX1100P can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through ROX .
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports For specifications on the available copper Ethernet ports, refer to Section 4.4, “Copper Ethernet Port Specifications”. Section 3.2 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Registered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors.
Chapter 3 RUGGEDCOM RX1100P Communication Ports Installation Guide Description Reserved (Do Not Connect) Reserved (Do Not Connect) Reserved (Do Not Connect) Section 3.4 DSL Ports The RX1100P can optionally be equipped with a dual-port DSL (Digital Subscriber Line) card, which can communicate over standard telephone communication lines.
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports Name Description Reserved (Do Not Connect) Reserved (Do Not Connect) Receive data from network (Tip) Receive data from network (Ring) Section 3.6 Modem Port The RX1100P can optionally be equipped with a V.90 Modem connection for PPP (Point-to-Point Protocol) connections.
Chapter 3 RUGGEDCOM RX1100P Communication Ports Installation Guide NOTE On power-up, all serial RJ45 ports default to RS485 mode. Each port can be individually set to RS232, RS485 or RS422 mode through ROX . For more information, refer to the ROX User Guide for the RX1100P.
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports Figure 26: PTP Card 1. IEEE 1588 Ethernet Interface 2. GPS Antenna Input 3. IRIG-B AM Output 4. IRIG-B PWM (TTL) or PPS Output 1 5. IRIG-B PWM (TTL) or PPS Output 2 NTP is the standard for synchronizing the clocks of computer systems throughout the Internet and is suitable for systems that require accuracies in the order of 1 ms.
Chapter 3 RUGGEDCOM RX1100P Communication Ports Installation Guide Figure 27: IRIG-B Simplified Schematic 1. Source 2. Cabling 3. Device The maximum number of devices (N) that can be connected to the source is determined by checking if the source current (IS) required to drive the connected devices is less than the maximum drive current the source can provide, and verifying that the load voltage (VL) the connected devices see is greater than the minimum required voltage.
The time delay is dependent on the type of dielectric material in the cable and ranges from 1 to 2 ns/ft. Siemens provides a method to account for this delay through the web management interface by entering the time delay into the cable compensation box under PTP General Configuration.
Siemens also recommends installing lightning arrestors in the antenna line to protect the receiver and connected devices. If a lightning arrestor is installed it is important to ensure that it has a low impedance path to ground.
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports Name Description Carrier Detect Receive data Transmit Data Data Terminal Ready Common Ground Data Set Ready Request To Send Figure 28: Serial DB9 Port Pin Configuration Clear To Send RI (No Ring Indicator...
Chapter 3 RUGGEDCOM RX1100P Communication Ports Installation Guide Figure 29: EVDO Cellular Modem The EVDO cellular modem has the following minimum requirements: Frequency Range (MHz) Maximum RX Diversity Band VSWR Allowable Support Gain (dBi) Cell 824-849 869-894 <2:1 <2:1 4.95...
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports Supported Frequency Bands WARNING! Electromagnet radiation hazard – risk of serious injury. Do not exceed the maximum antenna gain. Aside from causing cellular interference for other devices that use the same band, adverse health effects for individuals in the area may occur.
Chapter 3 RUGGEDCOM RX1100P Communication Ports Installation Guide Insert the SIM card with the angled side first. An audible click will indicate the SIM card is in position. Install the access panel. Connect power to the device. Supported Frequency Bands WARNING! Electromagnet radiation hazard –...
Page 37
RUGGEDCOM RX1100P Chapter 3 Installation Guide Communication Ports 120Ω 10nF 120Ω 10nF Figure 32: Recommended RS485 Wiring 1. RX1100P Device 2. Common (Isolated Ground) 3. Negative 4. Positive 5. Shield to Earth (Connected At a Single Point) 6. RS485 Devices (32 Total)
RUGGEDCOM RX1100P Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “PoE Power Supply Specifications” • Section 4.3, “Failsafe Relay Specifications”...
To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Power...
Chapter 4 RUGGEDCOM RX1100P Technical Specifications Installation Guide Section 4.8 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C Measured from a 30 cm (12 in) radius surrounding the center of the (-40 to 185 °F) enclosure.
RUGGEDCOM RX1100P Chapter 6 Installation Guide Certification Certification The RX1100P device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
Chapter 6 RUGGEDCOM RX1100P Certification Installation Guide Section 6.4 EMI and Environmental Type Tests The RX1100P has passed the following EMI and environmental tests. IEC 61850-3 EMI Type Tests NOTE • In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise, all Class 1 requirements are met for copper ports.
Page 49
RUGGEDCOM RX1100P Chapter 6 Installation Guide Certification Test Description Test Levels Severity Levels IEC 61000-4-12 Damped Oscillatory Signal ports 2.5 kV common, 1 kV differential mode @ 1 MHz DC Power ports 2.5kV common,1kV differential mode @ 1 MHz AC Power ports 2.5 kV common,...
Chapter 6 RUGGEDCOM RX1100P Certification Installation Guide Test Description Test Levels AC Power ports 2.5 kV common and differential mode @ 1 MHz IEEE C37.90 HV Impulse Signal ports 5 kV (Failsafe Relay) DC Power ports 5 kV AC Power ports 5 kV IEEE C37.90...