Fiber Optic Ethernet Port Specifications - Siemens RUGGEDCOM RMC40 Installation Manual

4-port unmanaged ethernet switch
Hide thumbs Also See for RUGGEDCOM RMC40:
Table of Contents

Advertisement

Chapter 4
Technical Specifications
e
Wiring Standard
f
Maximum Distance
g
Isolation
c
Auto-negotiating.
d
Shielded or unshielded.
e
Auto-crossover and auto-polarity.
f
Typical distance. Dependent on the number of connectors and splices.
g
RMS 1 minute.
Section 4.3

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber optic Ethernet ports that can be ordered with the RUGGEDCOM
RMC40.
NOTE
• All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens Sales associate when determining maximum segment
distances.
Data Rate
Mode
100 Mbps
MM
100 Mbps
SM
100 Mbps
SM
i
100 Mbps
MM
i
100 Mbps
MM
155 Mbps
SM
155 Mbps
SM
155 Mbps
SM
155 Mbps
SM
100 Mbps
MM
155 Mbps
SM
155 Mbps
SM
h
Typical.
i
Operating temperature: -10 to 85 °C (14 to 185 °F)
16
TIA/EIA T568A/B
100 m (328 ft)
1.5 kV
Wavelength (nm)
Cable
Connector
(μm)
Transmit
MTRJ
62.5/125
1300
LC
9/125
1300
SC
9/125
1300
ST
62.5/125
1300
SC
62.5/125
1300
SC
9/125
1550
SC
9/125
1310
SC
9/125
1310
ST
9/125
1310
ST
62.5/125
1300
LC
9/125
1310
LC
9/125
1310
h
Transmit Power (dBm)
Receive
Min
Max
1300
-19
-14
1300
-15
-8
1300
-15
-8
1300
-19
-14
1300
-19
-14
1310
 -14
-8
1550
-14
-8
1310
-5
 0
1310
-15
-8
1300
-20
-14
1310
-5
0
1310
0
5
RUGGEDCOM RMC40
Installation Guide
Receiver
Receiver
Sensitivity
Saturation
(dBm)
(dBm)
-31
-14
-33
-8
-31
-7
-30
-14
-30
-14
-33
0
-33
0
-35
-3
-34
-3
-31
-14
-35
0
-37
0
Fiber Optic Ethernet Port Specifications
Distance
h
(km)
2.5
15
15
2.5
2.5
20
20
40
15
2
40
90

Advertisement

Table of Contents
loading

Table of Contents