Fiber Optic Ethernet Port Specifications - Siemens Ruggedcom M2200 Installation Manual

Hide thumbs Also See for Ruggedcom M2200:
Table of Contents

Advertisement

RUGGEDCOM M2200
Installation Guide
Connector
Speed
e
Duplex
f
Cable Type
g
Wiring Standard
h
Maximum Distance
i
Isolation
e
Auto-Negotiating
f
Shielded or unshielded.
g
Auto-crossover and auto-polarity.
h
Typical distance. Dependent on the number of connectors and splices.
i
RMS 1 minute.
Section 5.5

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM M2200.
Gigabit Ethernet (1 Gbps) Optical Specifications
NOTE
These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20 to 85 °C (-4 to
185 °F) operation only.
Connector
Mode
Type
MM
LC
MM
LC
SM
LC
SM
LC
j
All cabling is duplex type unless specified otherwise.
k
Typical.
l
All optical power numbers are listed as dBm averages.
m
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
Fiber Optic Ethernet Port Specifications
micro-D
1000 Mbps
FDX/HDX
> CAT-5
TIA/EIA T568A/B
100 m (328 ft)
1.5 kV
Cable
k
Tx λ (nm)
j
Type (µm)
Minimum
50/125
850
62.5/125
850
9/125
1310
9/125
1310
l
Tx (dBm)
Rx
Sensitivity
Maximum
(dBm)
-9
-2.5
-20
-9
-2.5
-20
-9.5
-3
-21
-7
-3
-24
Technical Specifications
Rx
Distance
Saturation
m
(km)
l
l
(dBm)
0
0.5
0
0.5
-3
10
-3
25
Chapter 5
Power
Budget
(dB)
11
11
11.5
17
27

Advertisement