Plasma Console Connections - Lincoln Electric spirit II 150 Technical Manual

Automatic plasma cutting system with fineline high definition technology
Hide thumbs Also See for spirit II 150:
Table of Contents

Advertisement

Section 3: Installation

Plasma Console Connections

Perform the following steps to connect the plasma console to the Spirit system.
CAN Communications
• Insert the male end of the CAN communication cable. See "CAN Communication
Connections" for more details.
CAN Communications
• Insert the female end of the CAN communication cable or the CAN termination plug,
depending upon the connection scheme. See "CAN Communication Connections"
for more details.
RS-422 Communications
• Insert an RS-422 cable, if necessary, to connect to other devices.
RS-422 Communications
• Insert an RS-422 cable, if necessary, to connect to other devices.
USB
40
• Either USB port can be used to update the Spirit II software.
Ethernet
41
• No connection. For future development.
41
40
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
36
37
38
39
38
39
36
3-20
37
Spirit II User's Manual
RS-422 Pinout
1
3
4
6
7
9
Pin
Signal
1 .......... Gnd
2 .......... TX-
3 .......... TX+
4 .......... RX-
5 .......... RX+
6 .......... N/C
7 .......... N/C
8 .......... N/C
9 .......... N/C