Torch Leads to Arc Starting Console Connections

Perform the following steps to connect the torch leads to the arc starting console.
See Figure 6 on the next page.
Note: When making hose connections, only tighten the brass fittings enough to
make water or gas seals. The fittings are subject to damage if over tightened.
Braided Shield
1. Remove the threaded ring from the brass shield connector on the end of the braided
shield. Route the torch leads through the opening in the arc starting console and
push the shield connector through the hole until it is seated against the side of the
console.
2. Slide the threaded ring over the torch leads, thread it onto the brass shield
connector, and tighten firmly. The shield connector should ground the braided
shield to the case of the arc starting console in order to help reduce high frequency
noise emission. Using an ohmmeter, measure for zero ohms between the braided
shield and the ground stud located on the outside of the arc starting console.
Torch Electrode/Coolant Supply Lead
• Connect the torch electrode/coolant supply lead to the brass cathode manifold. Note
that the torch electrode/coolant supply lead has right hand threads.
Torch Coolant Return Lead
• For systems that include ACS with RHF, connect the torch coolant return lead to the
brass cathode manifold.
threads.
• For systems that include ACS with CleanStrike
coolant return lead to the brass elbow fitting on the ASC manifold. Note that the
torch coolant return lead has left hand threads.
Torch Nozzle Lead
• For systems that include ACS with RHF, connect the torch nozzle lead to the angled
bracket on the red standoff. Note that the torch nozzle lead has right hand threads.
• For systems that include ACS with CleanStrike
nozzle lead to the fitting on the red standoff. Note that the torch nozzle lead has
right hand threads.
Torch CTP Sensor Lead
• Connect the #18AWG torch CTP sensor lead to the red standoff as shown.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
11
13
Note that the torch coolant return lead has left hand
14
15
12
Technology, connect the torch
Technology, connect the torch
3-15
Section 3: Installation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents