Spirit II User's Manual
Command
Cutting Chart
Version
Number of Pierces
Number of Pierce
Errors
Reset Pierce
Counter
Power On
Power Off
Request System
Status
Purge Gases
Set Cutting Arc
Voltage
Set Cutting Height
Set Cutting Pierce
Height
Set Cutting Travel
Speed
Save as User File
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
#
Hex String
34
AA nn FA 22 00 -- 0D
35
AA nn FA 23 00 -- 0D
36
AA nn FA 24 00 -- 0D
37
AA nn FA 25 00 01 0D
38
AA nn FA 26 00 01 0D
39
AA nn FA 27 00 01 0D
40
AA nn FA 28 00 01 0D
41
AA nn FA 29 00 01 0D
42
AA nn FA 2A -- -- 0D
43
AA nn FA 2B -- -- 0D
44
AA nn FA 2C -- -- 0D
45
AA nn FA 2D -- -- 0D
46
AA nn FA 2E 00 01 0D
B-7
Appendix B: Serial Communication
Additional Information
If requested in command #30, the system will
transmit the cutting chart version x 10.
If requested in command #30, the system will
transmit the number of pierces. Range: 0 to 9999
If requested in command #30, the system will
transmit the number of pierce errors. Range: 0 to
9999
Resets number of pierces and errors to 0
Energizes power supply, torch coolant pump and
cooling fans. If torch coolant flow switch not
satisfied within 8 seconds, unit will power down.
Deenergizes power supply, torch coolant pump
and cooling fans
System status can only be requested after a
Power On command (#38) is transmitted. The
status is returned in the following form: (All bits:
0=fault; 1=ok)
LSB Bit 0 = ASC Door
LSB Bit 1 = AC Power
LSB Bit 2 = Coolant Flow
LSB Bit 3 = Coolant Level
LSB Bit 4 = Coolant Temp
LSB Bit 5 = AGC status
LSB Bit 6 = Inlet Gas Pressures
LSB Bit 7 = Not used
MSB Bit 0 = Not used
MSB Bit 1 = Hydrogen Cutting Enabled
Purges gas lines
Sets cutting arc voltage in Volts x 100
Valid Range: 5000 to 20000
Sets cutting height in mils (inches / 1000)
Valid Range: 0 to 999
Sets cutting pierce height in mils (inches / 1000)
Valid Range: 0 to 999
Sets cutting travel speed (inches / min) displayed
on the voltage screen
Valid Range: 0 to 999
Saves the present cutting conditions as a user
file.