Setting Items And Set Data - Mitsubishi FR-A500 Series Instruction Manual

Transistorized inverter: fr-a520-0.4k to 55k(-na) and fr-a540-0.4k to 55k(-na)(-ec)
Hide thumbs Also See for FR-A500 Series:
Table of Contents

Advertisement

<Setting items and set data>
After completion of parameter setting, set the instruction codes and data and start communication from
the computer to allow various types of operation control and monitoring.
No.
Item
Operation
1
mode
Output frequency
[speed]
Output current
Output voltage
Special monitor
Special monitor
selection No.
2
Alarm definition
Instruction
Code
H0000: Communication option operation
Read
H7B
H0001: External operation
H0002: Communication operation (PU connector)
H0000: Communication option operation
Write
HFB
H0001: External operation
H0002: Communication operation (PU connector)
H0000 to HFFFF: Output frequency (hexadecimal) in 0.01Hz
increments
H6F
[Speed (hexadecimal) in r/min increments if Pr. 37 = 1 to
9998 or Pr. 144 = 2 to 10, 102 to 110.]
H0000 to HFFFF: Output current (hexadecimal) in 0.01A
H70
increments
H0000 to HFFFF: Output voltage (hexadecimal) in 0.1V
H71
increments
H0000 to HFFFF: Monitored data selected by instruction code
H72
HF3
H01 to H0E
Data
Read
H73
H01
H02
H03
H05
Write
HF3
H06
H07
H0000 to HFFFF: Two most recent alarm definitions
(Previous alarm ........ THT)
(Most recent alarm ..... OPT)
Alarm data
H74 to H77
Description
Monitor selection data
Incre-
Description
Data
ments
Output
0.01Hz
H09
frequency
Output current
0.01A
H0A
Output voltage
0.1V
H0B
Frequency
0.01Hz
H0C
setting
Running speed
1 r/min
H0D
Motor torque
0.1%
H0E
Read data: [Example] H30A0
b15
0 0 1 1 0 0
Previous alarm
(H30)
Data
Description
Data
Description
H00
No alarm
H80
H10
0C1
H81
H11
0C2
H90
H12
0C3
HA0
H20
0V1
HA1
H21
0V2
HA2
H22
0V3
HA3
H30
THT
HB0
H31
THM
HB1
H40
FIN
HB2
H50
IPF
HC1
H51
UVT
HC2
H60
OLT
HD1
H70
BE
HD2
126
PARAMETERS
Incre-
Description
ments
Regenerative
0.1%
brake
Electronic
overcurrent
0.1%
protection load
factor
Output current
0.01A
peak value
Converter output
0.1V
voltage peak value
Input power
0.01kW
Output power
0.01kW
b8b7
b0
0
0
1
0
1
0 0 0 0 0
Most recent alarm
(HA0)
Data
Description
GF
HD5
MB1
LF
HD6
MB2
OHT
HD7
MB3
OPT
HD8
MB4
OP1
HD9
MB5
OP2
HDA
MB6
OP3
HDB
MB7
PE
HF1
E. 1
PUE
HF2
E. 2
RET
HF3
E. 3
CTE
HF6
E. 6
P24
HF7
E. 7
OSD
ECT
Number of
Data Digits
4 digits
4 digits
4 digits
4 digits
4 digits
2 digits
4 digits

Hide quick links:

Advertisement

Table of Contents
loading