4.2.26 Acceleration/deceleration reference current/lift mode starting
frequency (Pr. 61 to Pr. 64)
Pr. 61 "reference I for intelligent mode"
Pr. 62 "ref. I for intelligent mode accel."
Pr. 63 "ref. I for intelligent mode decel."
Pr. 64 "starting frequency for elevator mode"
! Set these parameters to improve performance in the intelligent mode.
Parameter
Factory
Number
Setting
61
62
63
64
<Setting>
( 1 ) Pr. 61 "reference I for intelligent mode"
Setting
9999 (factory setting)
0 to 500A
( 2 ) Pr. 62 "ref. I for intelligent mode accel."
(The reference value differs between the shortest acceleration/deceleration mode and optimum
acceleration/deceleration mode.)
The reference current setting can be changed.
Setting
9999 (factory setting)
0 to 200%
( 3 ) Pr. 63 "ref. I for intelligent mode decel."
(The reference value differs between the shortest acceleration/deceleration mode and optimum
acceleration/deceleration mode.)
The reference current setting can be changed.
Setting
9999 (factory setting)
0 to 200%
( 4 ) Pr. 64 "starting frequency for elevator mode"
Setting
9999 (factory setting)
0 to 10Hz
Note: Pr. 61 to Pr. 64 are only valid when any of "1 to 6" is selected for Pr. 60.
Setting Range
9999
0 to 500A, 9999
9999
0 to 200%, 9999
9999
0 to 200%, 9999
9999
0 to 200%, 9999
Referenced from rated inverter current
Referenced from setting (rated motor current)
150% (180%) is the limit value.
100% is the optimum value.
The setting of 0 to 200% is the limit value.
The setting of 0 to 200% is the optimum
value.
150% (180%) is the limit value.
100% is the optimum value.
The setting of 0 to 200% is the limit value.
The setting of 0 to 200% is the optimum
value.
2Hz is the starting frequency.
The setting of 0 to 10Hz is the starting frequency.
Pr. 60 "intelligent mode selection"
Remarks
9999: Referenced from rated inverter
current.
Reference Current
Reference Current
Reference Current
Reference Current
94
PARAMETERS
Related parameter
Remarks
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Remarks
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode