Avaya 4500 Series Installation Manual page 46

Ethernet routing switch
Hide thumbs Also See for 4500 Series:
Table of Contents

Advertisement

Installing the Avaya Ethernet Routing Switch
1. Connect a terminal to the console port of the switch.
2. Set the terminal protocol on the terminal or terminal emulation program to VT100
3. Connect to the switch using the terminal or terminal emulation application.
4. When the switch configuration is set to factory default the following screen appears.
46
Installation
You can use any terminal or PC with an appropriate terminal emulator as the
management station.The following table lists the parameters that you must use with
any terminal emulation software used to connect to the switch.
Property
Baud Rate
Data Bits
Stop Bits
Parity
Flow Control
You require a console cable and connector to match the male DTE connector (DB-9)
on the switch to connect the terminal to the switch console port.
Note:
Autobaud is not supported. If you change the terminal speed and then reboot the
unit, non relevant characters appear in the display. Workaround: Use only 9600
(baud rate) for terminal speed.
and VT100/ANSI.
Enter the information requested at each prompt.
Welcome to the 4548GT-PWR setup utility. You will be
requested for information to initially configure for the
switch. When finished the information will be applied and
stored in the switch NVRAM.
configured, additional configuration can proceed using other
management interfaces. Press ^C to abort at any time.
The in-band IP Address prompt line appears
Please provide the in-band IP Address[0.0.0.0]:10.127.232.30
The in-band sub-net mask prompt line appears
Please provide the in-band sub-net mask[0.0.0.0]:
255.255.255.0
The Default Gateway prompt line appears
Value
9600 bps
8
1
None
None