This option is valid only if a WWN is present in the Attached WWN column, indicating that
the WWN that is currently attached to the port, but is not bound to it.)
If Port Binding enabled, and a WWN is not specified for binding, no devices can attach to
NOTE:
the port.
4.
Click OK to save the information.
The following message is displayed:
Your changes have been successfully activated

Configuring zoning

The default zone on the Edge Switch is disabled by default. Zoning must be configured in order for
any devices connected to the Edge Switch to communicate. Perform this procedure to configure,
change, add, or delete zones or zone sets.
A zone is a group of devices that can access each other through port-to-port connections.
Devices in the same zone can recognize and communicate with each other; devices in different
zones cannot.
A zone set is a group of zones that is activated or deactivated as a single entity across all
managed products in either a single-switch or a multiswitch fabric. Only one zone set can be
active at one time.
The following naming conventions apply to zones and zone sets:
• All names must be unique and may not differ by case only. For example, zone-1 and Zone-1
are both valid individually, but are not considered unique.
• The first character of a zone set name must be a letter (A through Z or a through z).
• A zone set name can have a maximum of 64 characters and cannot contain spaces.
• Valid characters are alphanumerical and the caret (^), hyphen (-), underscore (_), or dollar
($) symbols.
For instructions about configuring zones and zone sets, see the HAFM Basic user guide.