Table 10

Port/device icons

Icon

Configuring the zoning database

Use the Zoning Config dialog box
Inactive configuration parameters. To open the Zoning Config dialog box, select Zoning > Edit Zoning
Config. After making the changes, click OK to put the new values into effect.
Figure 29

Zoning Config dialog box

Merge Auto Save

The Merge Auto Save parameter determines whether changes to the active zone set that a switch receives
from other switches in the fabric are saved to the zoning database on that switch. Changes are saved
when an updated zone set is activated. Zoning changes are always saved to temporary memory.
If Merge Auto Save is enabled, the switch firmware saves changes to the active zone set in temporary
memory and to the zoning database.
If Merge Auto Save is disabled, changes to the active zone set are stored only in temporary memory,
which is cleared when the switch is reset.
NOTE:
Disabling the Merge Auto Save parameter can be useful to prevent the propagation of zoning
information when experimenting with different zoning schemes. However, leaving the Merge Auto Save
parameter disabled can disrupt device configurations should a switch have to be reset. For this reason, the
Merge Auto Save parameter should be enabled in a production environment.
54
Managing Fabric Zoning
Description
Switch port icon—When not logged in
Switch port icon—When logged in
NL_Port (loop) device icon—When logged in to fabric
NL_Port (loop) device icon—When not logged in to fabric
N_Port device icon—When logged in to fabric
N_Port device icon—When not logged in to fabric
(Figure
29) to change the Merge Auto Save, Default Zone, and Discard

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sn6000

Table of Contents