DigitalMedia™ Switchers
Restore Defaults
166
DigitalMedia™ Switchers: DM-MD8X8/16X16/32X32
Audio Details
Audio
Format: PCM
Frequency: 48.0kHz
Channels: 2
ii. Press the MENU button to return to the Loopback Settings.
c.
To view EDID information about the display device connected to the
HDMI OUT port:
i. Turn the selection knob to highlight EDID Information and press
the ENTER button.
EDID Information
EDID Information
Manufacturer: SHP
Name: SHARP HDMI
Timing: 1920x1080 @ 60Hz
ii. Press the MENU button to return to the Loopback Settings.
3. Press the MENU button to return to the list of options for the input card.
Use the Restore Defaults function to reset the card to its factory settings. The card's
factory settings are:
Loopback Allow Deep Color: On
Color Space Mode: Force RGB
Enable/Disable input: Input enabled
Brightness level: 0
Contrast level: 0
Saturation level: 0
Hue level: 0

To restore the card's default settings:

1. Turn the selection knob to highlight Restore Defaults and press the
ENTER button.