3.4 Ring s and To nes

3.4.1 Ring Cycles

OfficeServ 7030 provides the trunk line rings, station rings, door rings, and alarm rings.
The ON/OFF cycle of each ring is shown in the table below:
Trunk line ring
Station ring
Door ring
Alarm ring
Ring ON/OFF Cycle
The ON/OFF cycle can be adjusted by changing the values of the system
database.
3.4.2 To nes
The output voltage and the frequency of the ring signals in OfficeServ 7030 are as follows:
Output voltage: 75 V
Ÿ
Frequency: 20 Hz
Ÿ
OfficeServ 7030 provides the users with various tones to notify the users of the status of
functional operation and give feedback to the users. The ON/OFF cycles of currently
specified tones are shown in the table below:
Dial tone
Busy Tone
Do Not Disturb tone
Ring Back tone
Call Park tone
Confirmation/Caution/Barge-In tone
Call Back/Hold tone
Ring Back tone
Error/Number Unobtainable tone
Message Camp On tone
© SAMSUNG Electronics Co., Ltd.

Table 3.10 System Ring Cycles

Ring s
Table 3.11 Cycles o f the System To nes
To nes
OfficeServ 7030 System Descriptio n
ON/OFF Cycles
1000/3000 ms
400/200/400/3000 ms
400/200/400/200/400/2000 ms
400/200/400/200/400/200/400/1000 ms
ON/OFF Cycles
1000/250 ms
500/500 ms
250/250 ms
1000/2000 ms
Continuous
50/50 ms
500/3500 ms
1000/2000 ms
250/250 ms
Continuous
3-7