logging {ip-address | ipv6-address | hostname} {{udp {port}} | {tcp {port}}}

Configuring a UNIX System as a Syslog Server

To configure a UNIX System as a syslog server, use the following command.
Configure a UNIX system as a syslog server by adding the following lines to /etc/syslog.conf on the UNIX
system and assigning write permissions to the file.
Add line on a 4.1 BSD UNIX system. local7.debugging /var/log/ftos.log
Add line on a 5.7 SunOS UNIX system. local7.debugging /var/adm/ftos.log
In the previous lines, local7 is the logging facility level and debugging is the severity level.
Display the Logging Buffer and the
Logging Configuration
To display the current contents of the logging buffer and the logging settings for the system, use the show
logging command in EXEC privilege mode. When RBAC is enabled, the security logs are filtered based on
the user roles. Only the security administrator and system administrator can view the security logs.
Example of the show logging Command
Dell#show logging
Syslog logging: enabled
Console logging: level debugging
Monitor logging: level debugging
Buffer logging: level debugging, 416 Messages Logged, Size (40960 bytes)
Trap logging: level informational
Logging to 10.1.2.4
Logging to 172.31.1.4
Logging to 133.33.33.4
Logging to 172.16.1.162
Logging to 10.10.10.4
Jan 21 09:52:21: %SYSTEM:CP %SYS-5-CONFIG_I: Configured from vty0 ( 10.11.8.68 )by
admin
Jan 21 09:32:57: %SYSTEM:CP %SYS-5-CONFIG_I: Configured from vty0 ( 10.11.8.68 )by
admin
Jan 21 09:32:57: %SYSTEM:CP %SEC-3-AUTHENTICATION_ENABLE_SUCCESS: Enable password
authentication success on vty0 ( 10.11.8.68 )
Jan 21 09:32:57: %SYSTEM:CP %SEC-5-LOGIN_SUCCESS: Login successful for user admin
on line vty0 ( 10.11.8.68 )
Jan 21 04:11:02: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:
Te 0/1
Jan 21 04:11:02: %SYSTEM:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:
Te 0/0
Jan 21 03:12:54: %SYSTEM:LP %CHMGR-2-PSU_FAN_SPEED_CHANGE: PSU_Fan speed changed
to 60 % of the full speed
Jan 21 03:12:54: %SYSTEM:LP %CHMGR-2-FAN_SPEED_CHANGE: Fan speed changed to 40 %
of the full speed
Jan 21 03:02:51: %SYSTEM:LP %CHMGR-2-PSU_FAN_SPEED_CHANGE: PSU_Fan speed changed
to 80 % of the full speed
Jan 21 03:02:51: %SYSTEM:LP %CHMGR-2-FAN_SPEED_CHANGE: Fan speed changed to 50 %
of the full speed
Jan 21 02:56:54: %SYSTEM:CP %SNMP-6-SNMP_WARM_START: Agent Initialized - SNMP
WARM_START.
Switch Management
77