6. 34. 9
<F721: Panel stop>
■ Function
This parameter is used to select a panel stop pattern by pressing the [STOP] key on the operation
4
panel from Deceleration stop or Coast stop.
■ Parameter setting
4
Title
6
F721
■ Selecting a setting value
0: Deceleration stop
The motor decelerate to a stop in the deceleration time set with <dEC: Deceleration time 1>.
9
1: Coast stop
The inverter cuts off power supply to the motor. The motor comes to a stop after coasting for a while.
Depending on the load, the motor may keep running for a longer time.
Reference
6. [Advanced] How to use parameters

Selecting panel stop pattern

Parameter name
Panel stop
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
F721 : Panel stop
0: Deceleration stop
1: Coast stop
Adjustment range
0: Deceleration stop
1: Coast stop
6-174
E6582062
STOP
0.0Hz
14:14
Default setting
0