Input Signals To The Control Terminals; Selecting Operation At Simultaneous Input Of Fwd/Rev Commands; Difference Between The Settings - Toshiba TOSVERT VF-AS3 Instruction Manual

Industrial inverter (for 3-phase motors)
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

6. 2

Input signals to the control terminals

Various signals are input to the inverter for motor operation.
For details on the input terminal function, refer to [7. 2. 1].
6. 2. 1
Selecting operation at simultaneous input of Fwd/
Rev commands
<F105: Fwd/Rev priority of both close>
■ Function
This parameter selects operation performed (reverse run or deceleration stop) when the Fwd and
Rev signals are simultaneously input.
■ Parameter setting
Title
Parameter name
F105
Fwd/Rev priority of both
close

■ Difference between the settings

0: Reverse
When the Fwd and Rev signals are simultaneously input, reverse run is performed.
Frequency command value
Frequency command value
Terminal [F]
(Fwd run)
Terminal [R]
(Rev run)
0: Reverse
1: Stop
Output frequency (Hz)
0
6-7
STOP
F105 : Fwd/Rev priority
0: Reverse
1: Stop
Adjustment range
Fwd
Time (s)
Rev
ON
OFF
ON
OFF
6. [Advanced] How to use parameters
E6582062
0.0Hz
12:45
3
4
6
9
Default setting
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents