Advanced Settings Menu
Vertical Active
Vertical Refresh Rate
Fully Specified
Pixel Clock
Horizontal Blanking
Horizontal Front Porch
Horizontal Sync Width
Vertical Blanking
Vertical Front Porch
Vertical Sync Width
52
The number of active lines in a field
Range: 0~4095
The number of fields per second rounded to the nearest Hz
Range: 0~120
Determine how the final detailed timing is calculated. If disabled, it is calculated based on
Horizontal Active, Vertical Active, and Vertical Refresh Rate values. If enabled, it is
calculated based on all of the EDID values except for Vertical Refresh Rate.
Options: Disabled, Enabled
Note: This setting should only be enabled by advanced users.
The value of the pixel clock, in megahertz
Range: 0~600.00, in 0.01 increments
The number of non-active pixel clocks in a line
Range: 0~1023
The number of pixel clocks in the horizontal front porch
Range: 0~1023
The number of pixel clocks in the horizontal sync pulse
Range: 0~255
The number of non-active lines in a field
Range: 0~255
The number of line times in the vertical front porch
Range: 0~255
The number of line times in the vertical sync
Range: 0~255