Important Waste Disposal Information
Please recycle or dispose of all electronic waste in accordance with local, state, and
federal laws. Additional resources can be found online at
http://www.planar.com/about/green/.
Normal Usage Guidelines
Normal use of the LCD is defined as operating in the open air to prevent heat
buildup, and without direct or indirect heat sources such as lighting fixtures, heating
ducts, or direct sunlight that can cause the displays to experience high operating
temperatures. For all displays, do not block fans or ventilation openings. If the LCD
display will be installed in a recessed area with an LCD surround or enclosure, ensure
adequate openings are applied for proper air flow and ventilation.
It is up to the installer to ensure that display placement is changed, thermal shielding
is provided and/or additional ventilation is provided to keep the display within its
nominal operating parameters. Maximum ambient operating temperatures for the
Planar UltraRes Series are:
Cooling Requirements
For optimal performance, active cooling by the installer should be planned for when
the ambient temperature anywhere in the wall is predicted to be above the specified
ambient temperature for the display.
• 75" Planar UltraRes models: 0-40°C at up to 1500 meters and 0-35°C at up to
3000 meters
• 86" and 98" Planar UltraRes models: 0-35°C at up to 1500 meters and 0-30°C at
up to 3000 meters