Grandstream Networks UCM6200 User Manual page 279

Ip pbx
Hide thumbs Also See for UCM6200:
Table of Contents

Advertisement

Registration/Subscript
ion Time
Min
Registration/Subscript
ion Time
Enable Relaxed DTMF
DTMF Mode
RTP Timeout
RTP Hold Timeout
RTP Keep-alive
100rel
Trust Remote Party ID
Send Remote Party ID
Generate In-Band
Ringing
Server User Agent
subscription allowed by the UCM6200. The default setting is 3600.
Configure the minimum duration (in seconds) of incoming registration and
subscription allowed by the UCM6200. The default setting is 60.
Select to enable relaxed DTMF handling. The default setting is "No".
Select DTMF mode to send DTMF. The default setting is RFC2833. If "Info" is
selected, SIP INFO message will be used. If "Inband" is selected, 64-kbit codec
PCMU and PCMA are required. When "Auto" is selected, "RFC2833" will be used
if offered, otherwise "Inband" will be used. The default setting is "RFC2833".
During an active call, if there is no RTP activity within the timeout (in seconds),
the call will be terminated. The default setting is no timeout.
Note:
This setting doesn't apply to calls on hold.
When the call is on hold, if there is no RTP activity within the timeout (in seconds),
the call will be terminated. This value of RTP Hold Timeout should be larger than
RTP Timeout. The default setting is no timeout.
This feature can be used to avoid abnormal call drop when the remote provider
requires RTP traffic during proceeding.
For example, when the call goes into voicemail and there is no RTP traffic sent
out from UCM, configuring this option can avoid voicemail drop.
When configured, RTP keep-alive packet will be sent to remote party at the
configured interval. If set to 0, RTP keep-alive is disabled.
Configure the 100rel setting on UCM6200. The default setting is "Yes".
Configure whether the Remote-Party-ID should be trusted. The default setting is
"No".
Configure whether the Remote-Party-ID should be sent or not. The default setting
is "No".
Configure whether the UCM6200 should generate inband ringing or not. The
default setting is "Never".
Yes: The UCM6200 will send 180 Ringing followed by 183 Session Progress
and in-band audio.
No: The UCM6200 will send 180 Ringing if 183 Session Progress has not
been sent yet. If audio path is established already with 183 then send in-band
ringing.
Never: Whenever ringing occurs, the UCM6200 will send 180 Ringing as long
as 200OK has not been set yet. Inband ringing will not be generated even the
end point device is not working properly.
Configure the user agent string for the UCM6200.
UCM6200 Series User Manual