6-7 ELECTRICAL SYSTEM
GENERATOR COIL CONTINUITY INSPECTION
• Remove the frame covers and seat_
• Disconnect the generator lead wire coupler
CD.
Using a pocket tester, inspect the continuity between the
three lead wires.
If there is no continuity, replace the generator coil with a
new one .
• MOlt
09900-25002: Pocket tester
~Tester
knob indication: X
Hl
range
GENERATOR NO-LOAD PERFORMANCE INSPECTION
• Remove the frame covers and seat.
• Disconnect the generator lead wire coupler
CD .
• Start the engine and keep it running at 5 000 r/min.
Using a pocket tester, measure the voltage between the
three lead wires.
If the tester reads under the specified value, replace the
generator coil with a new one.
Eib
09900-25002: Pocket tester
~
Tester knob indication: AC250V
Generator no-load performance:
More than 75V/5 000 r/min
(When engine is cold)