Toshiba PORTEGE S100 Maintenance Manual page 58

Hide thumbs Also See for PORTEGE S100:
Table of Contents

Advertisement

2.4 System Board Troubleshooting
Check 3
PORTEGE S100 Maintenance Manual (960-508)
Downloaded from LpManual.com Manuals
The IRT checks the system board. When the IRT detects an error, the system
stops or an error message appears.
If one of the following error messages (1) through (17), (22) or (23) is displayed,
go to Procedure 4.
If error message (18) is displayed, go to the Keyboard Troubleshooting
Procedures in Section 2.7.
If error message (19), (20) or (21) is displayed, go to the 2.5" HDD
Troubleshooting Procedures in Section 2.6.
(1)
PIT ERROR
(2)
MEMORY REFRESH ERROR
(3)
TIMER CH.2 OUT ERROR
(4)
CMOS CHECKSUM ERROR
(5)
CMOS BAD BATTERY ERROR
(6)
FIRST 64KB MEMORY ERROR
(7)
FIRST 64KB MEMORY PARITY ERROR
(8)
VRAM ERROR
(9)
SYSTEM MEMORY ERROR
(10) SYSTEM MEMORY PARITY ERROR
(11) EXTENDED MEMORY ERROR
(12) EXTENDED MEMORY PARITY ERROR
(13) DMA PAGE REGISTER ERROR
(14) DMAC #1 ERROR
(15) DMAC #2 ERROR
(16) PIC #1 ERROR
(17) PIC #2 ERROR
(18) KBC ERROR
(19) HDC ERROR
(20) HDD #0 ERROR
(21) HDD #1 ERROR
(22) TIMER INTERRUPT ERROR
(23) RTC UPDATE ERROR
2 Troubleshooting Procedures
2-17

Advertisement

Table of Contents
loading

Table of Contents