18 Contracture Foot assembly
18.1 Adjusting the Angle of the Contracture Assembly
Bilateral Contracture Footplate
1.
Remove the top mounting bolt and locknut that secures the
contracture support tube to the angle adjustment plate.
2.
Rotate the contracture support tube and align with one of the nine
mounting holes in the angle adjustment plate.
3.
Reinstall the mounting bolt and locknut. Securely tighten.
4.
Perform STEPS 1 -4 for remaining footplate.
Contracture Platform
1.
Remove the top mounting bolt and locknut that secures the
contracture support tube to the angle adjustment plate.
2.
Rotate the contracture support tube and align with one of the nine
mounting holes in the angle adjustment plate.
3.
Reinstall the mounting bolt and locknut. Securely tighten.
Part No 1154295
18 CONTRACTURE FOOT ASSEMBLY
Top Mounting
Bolt and
Locknut
Angle
Adjustment
Plate
Contracture
Support Tube
Mounting
Holes
FIGURE 1
Adjusting the Angle of the Contracture Assembly
123
Invacare® Solara®3G/Spree 3G Wheelchair
Mounting Holes
Angle
Adjustment
Plate
Top Mounting
Bolt and
Locknut
Contracture
Support Tube