87L Trip Logic (Read/Write Grouped Setting); Stub Bus (Read/Write Grouped Setting); 50Dd Disturbance Detection (Read/Write Grouped Setting); Frequency Out-Of-Band Accumulation (Read/Write Setting) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name

87L Trip Logic (Read/Write Grouped Setting)

L90
5EE0
"
5EE1
"
5EE2
"
5EE3
"
5EE5
2
"
5EE7
"
5EE8
"
5EE9
"
5EEA

Stub Bus (Read/Write Grouped Setting)

L30, L90
5F10
"
5F11
"
5F13
"
5F15
"
5F17

50DD Disturbance Detection (Read/Write Grouped Setting)

L30, L90
5F20
"
5F21
"
5F23
"
5F25
"
5F27

Frequency Out-Of-Band Accumulation (Read/Write Setting)

G30, G60
5F40
"
5F42
"
5F43
"
5F4A
"
5F51
"
5F52
"
5F53
"
5F54
"
5F5B
"
5F62
Setting Groups (Read/Write Setting)
All except C30
5F70
"
5F71
"
5F73
"
5F7D
"
5F7E
2-68
87L Trip Function
87L Trip Source
87L Trip Mode
87L Trip Supervision
87L Trip Force 3 Phase
87L Trip Seal In
87L Trip Seal In Pickup
87L Trip Target
87L Trip Events
Stub Bus Function
Stub Bus Disconnect
Stub Bus Trigger
Stub Bus Target
Stub Bus Events
50DD Function
50DD Non Current Supervision
50DD Control Logic
50DD Logic Seal In
50DD Events
Frequency Out-Of-Band Accumulation
Block
Frequency Out-Of-Band Accumulation
Events Enable
Frequency Out-Of-Band Accumulator
Function Enable Array (7 items)
Frequency Out-Of-Band Accumulator
Lower Frequency Array (7 items)
Frequency Out-Of-Band Accumulator Min
Value V A
Frequency Out-Of-Band Accumulator
Source
Frequency Out-Of-Band Accumulator
Target Messages Enable
Frequency Out-Of-Band Accumulator Time
Limit Array (7 items)
Frequency Out-Of-Band Accumulator Time
Preset Array (7 items)
Frequency Out-Of-Band Accumulator
Upper Frequency Array (7 items)
Setting Group for Modbus Comms (0
means group 1)
Setting Groups Block
FlexLogic Operands to Activate Groups 2
through 6 (5 items)
Setting Group Function
Setting Group Events
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0.2 to 0.8
pu
0.01
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 1
---
1
20 to 70
Hz
0.01
0.1 to 1.25
pu
0.01
0 to 5
---
1
0 to 2
---
1
1 to 65535
sec
1
0 to 65535
sec
1
20 to 70
Hz
0.01
0 to 5
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 1
---
1
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
F102
0 (Disabled)
F167
0 (SRC 1)
F157
0 (3-Pole)
F300
0
F300
0
F102
0 (Disabled)
F001
20
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F300
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F300
0
F300
0
F300
0
F102
0 (Disabled)
F300
0
F102
0 (Disabled)
F102
0 (Disabled)
F001
6000
F001
10
F167
0 (SRC 1)
F109
0 (Self-reset)
F001
200
F001
0
F001
6000
F001
0
F300
0
F300
0
F102
0 (Disabled)
F102
0 (Disabled)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents